Determination of elemental compositions by gas chromatography/time-of-flight mass spectrometry using chemical and electron ionization

被引:50
作者
Abate, Salvatore [2 ]
Ahn, Yun Gyong [1 ,3 ]
Kind, Tobias [1 ]
Cataldi, Tommaso R. I. [2 ]
Fiehn, Oliver [1 ]
机构
[1] UC Davis Genome Ctr, Davis, CA 95616 USA
[2] Univ Basilicata, Dept Chem, I-85100 Potenza, Italy
[3] Korea Basic Sci Inst, Seoul 136701, South Korea
关键词
ORGANIC-COMPOUNDS; RESOLUTION; IDENTIFICATION; ACCURACY;
D O I
10.1002/rcm.4482
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many metabolomic applications use gas chromatography/mass spectrometry (GC/MS) under standard 70 eV electron ionization (El) parameters. However, the abundance of molecular ions is often extremely low, impeding the calculation of elemental compositions for the identification of unknown compounds. On changing the beam-steering voltage of the ion source, the relative abundances of molecular ions at 70 eV El were increased up to ten-fold for alkanes, fatty acid methyl esters and trimethylsilylated metabolites, concomitant with 2-fold absolute increases in ion intensities. We have compared the abundance, mass accuracy and isotope ratio accuracy of molecular species in El with those in chemical ionization (CI) with methane as reagent gas under high-mass tuning. Thirty-three peaks of a diverse set of trimethylsilylated metabolites were analyzed in triplicate, resulting in 342 ion species ([M+H](+), [M-CH3](+) for CI and [M](+), [M-CH3](+center dot) for EI). On average, CI yielded 8-fold more intense molecular species than El. Using internal recalibration, average mass errors of 1.8 +/- 1.6 mm/z units and isotope ratio errors of 2.3 +/- 2.0% (A+1/A ratio) and 1.7 +/- 1.8% (A+2/A ratio) were obtained. When constraining lists of calculated elemental compositions by chemical and heuristic rules using the Seven Golden Rules algorithm and PubChem queries, the correct formula was retrieved as top hit in 60% of the cases and within the top-3 hits in 80% of the cases. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1172 / 1180
页数:9
相关论文
共 20 条
  • [1] Gas chromatography-mass spectrometry with supersonic molecular beams
    Amirav, Aviv
    Gordin, Alexander
    Poliak, Marina
    Fialkov, Alexander B.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2008, 43 (02): : 141 - 163
  • [2] IMPORTANCE OF ENHANCED MASS RESOLUTION IN REMOVING INTERFERENCES WHEN MEASURING VOLATILE ORGANIC-COMPOUNDS IN HUMAN BLOOD BY USING PURGE-AND-TRAP GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    BONIN, MA
    ASHLEY, DL
    CARDINALI, FL
    MCCRAW, JM
    PATTERSON, DG
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (08) : 831 - 841
  • [3] Importance of the electron mass in the calculations of exact mass by time-of-flight mass spectrometry
    Ferrer, Imma
    Thurman, E. Michael
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (15) : 2538 - 2539
  • [4] Identification of uncommon plant metabolites based on calculation of elemental compositions using gas chromatography and quadrupole mass spectrometry
    Fiehn, O
    Kopka, J
    Trethewey, RN
    Willmitzer, L
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (15) : 3573 - 3580
  • [5] Extending the breadth of metabolite profiling by gas chromatography coupled to mass spectrometry
    Fiehn, Oliver
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (03) : 261 - 269
  • [6] Quality control for plant metabolomics: reporting MSI-compliant studies
    Fiehn, Oliver
    Wohlgemuth, Gert
    Scholz, Martin
    Kind, Tobias
    Lee, Do Yup
    Lu, Yun
    Moon, Stephanie
    Nikolau, Basil
    [J]. PLANT JOURNAL, 2008, 53 (04) : 691 - 704
  • [7] Halket John M., 2005, Journal of Experimental Botany, V56, P219
  • [8] KIND T, 2007, 7 GOLDEN RULES
  • [9] Seven Golden Rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometry
    Kind, Tobias
    Fiehn, Oliver
    [J]. BMC BIOINFORMATICS, 2007, 8 (1)
  • [10] Metabolomic database annotations via query of elemental compositions:: Mass accuracy is insufficient even at less than 1 ppm
    Kind, Tobias
    Fiehn, Oliver
    [J]. BMC BIOINFORMATICS, 2006, 7 (1)