Role of tip injection in desensitizing the compressor to the tip clearance size

被引:33
作者
Khaleghi, Hossein [1 ]
Dehkordi, Mohammad-Amin Sheikhshahrokh [1 ]
Tousi, Abolghasem M. [1 ]
机构
[1] Amirkabir Univ Technol, Ctr Excellence Computat Aerosp Engn, Dept Aerosp Engn, Tehran 158754413, Iran
关键词
Tip clearance size; Leakage flow; Endwall injection; Stability enhancement; Transonic compressor; TRANSONIC AXIAL COMPRESSOR; ROTATING STALL; STABILITY; FLOW; PERFORMANCE; SURGE; FAN;
D O I
10.1016/j.ast.2016.02.003
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Numerical simulations are performed to investigate the role of tip injection in desensitizing a transonic compressor rotor to the detrimental effects of tip leakage flow. First, the effects of tip clearance size on the compressor stability and performance are investigated. Endwall injection of high-speed fluid upstream of the blade is then applied to the compressor with different tip clearance sizes. Results reveal that tip injection can effectively desensitize the compressor stability to the tip clearance size and improve the total pressure ratio, at the expense of some efficiency loss. It is further found that the larger the tip clearance size, the greater the stability enhancement and the smaller the efficiency penalty due to injection. The near-stall endwall flow structures for different tip clearance sizes, with and without injection, are also investigated in the current study. Results suggest that tip clearance size does not influence the compressor stalling mode, whereas endwall injection has the potential to change it (i.e., from "wall-stall" to "blade-stall" with the injection applied in the current study). (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 31 条
[1]   THE ROLE OF TIP CLEARANCE IN HIGH-SPEED FAN STALL [J].
ADAMCZYK, JJ ;
CELESTINA, ML ;
GREITZER, EM .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1993, 115 (01) :28-39
[2]  
[Anonymous], GT201425042 ASME
[3]  
[Anonymous], 2004372 AIAA
[4]  
[Anonymous], 1989, NASA TP 2879
[5]   Parametric study of tip clearance - Casing treatment on performance and stability of a transonic axial compressor [J].
Beheshti, BH ;
Teixeira, JA ;
Ivey, PC ;
Ghorbanian, K ;
Farhanieh, B .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2004, 126 (04) :527-535
[6]   Flow Characteristics of Tip Injection on Compressor Rotating Spike via Time-Accurate Simulation [J].
Chen, Jen-Ping ;
Johnson, Benjamin ;
Hathaway, Michael D. ;
Webster, Robert S. .
JOURNAL OF PROPULSION AND POWER, 2009, 25 (03) :678-687
[7]   Effects of Fan Speed on Rotating Stall Inception and Recovery [J].
Choi, Minsuk ;
Vahdati, Mehdi ;
Imregun, Mehmet .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2011, 133 (04)
[8]   ACTIVE SUPPRESSION OF ROTATING STALL AND SURGE IN AXIAL COMPRESSORS [J].
DAY, IJ .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1993, 115 (01) :40-47
[9]   Experiments in active control of stall on an aeroengine gas turbine [J].
Freeman, C ;
Wilson, AG ;
Day, IJ ;
Swinbanks, MA .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1998, 120 (04) :637-647
[10]   FUNDAMENTAL CRITERION FOR THE APPLICATION OF ROTOR CASING TREATMENT [J].
GREITZER, EM ;
NIKKANEN, JP ;
HADDAD, DE ;
MAZZAWY, RS ;
JOSLYN, HD .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1979, 101 (02) :237-243