Analysis of counting measurements on narrowband frequency up-converted single photons and the influence of heralding detector dead time

被引:4
作者
Fiurasek, Jaromir [1 ]
Baune, Christoph [2 ,3 ]
Schonbeck, Axel [2 ,3 ]
Schnabel, Roman [2 ,3 ,4 ,5 ]
机构
[1] Palacky Univ, Dept Opt, Olomouc 77146, Czech Republic
[2] Leibniz Univ Hannover, Inst Gravitat Phys, D-30167 Hannover, Germany
[3] Albert Einstein Inst, Max Planck Inst Gravitat Phys, D-30167 Hannover, Germany
[4] Univ Hamburg, Inst Laserphys, D-22761 Hamburg, Germany
[5] Univ Hamburg, Zentrum Opt Quantentechnol, D-22761 Hamburg, Germany
来源
PHYSICAL REVIEW A | 2015年 / 91卷 / 01期
关键词
QUANTUM; DISTILLATION; CONVERSION; THRESHOLD; LIGHT;
D O I
10.1103/PhysRevA.91.013829
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a theoretical model of photon counting measurements on conditionally generated narrowband single-photon states that are produced via cavity-enhanced spontaneous parametric down-conversion, then frequency up-converted from the telecom wavelength of 1550 nm to the visible wavelength of 532 nm. The highly nonclassical character of the up-converted states is certified by a quantum non-Gaussianity witness that is determined from coincidence measurements with single-photon detectors in a Hanbury-Brown-Twiss configuration. We find our model in good agreement with the experimental data, and we investigate a useful effect caused by the dead time of the trigger detector, whose clicks herald conditional preparation of the single-photon state. Due to the dead time, a click of the trigger detector excludes the possibility of a trigger event at a certain preceding time interval, during which the measured idler beam is thus projected onto a vacuum state. Due to quantum correlations between signal and idler beams, this reduces the multiphoton contributions in the conditionally generated state of the signal beam and accordingly increases the value of the quantum non-Gaussianity witness. We also show that spurious heralding detections due to after-pulsing can be suppressed by accepting a click of the trigger detector only if its distance from a previous click of this detector exceeds a certain suitably chosen threshold.
引用
收藏
页数:10
相关论文
共 45 条
[1]   Efficient single-photon counting at 1.55 μm by means of frequency upconversion [J].
Albota, MA ;
Wong, FNC .
OPTICS LETTERS, 2004, 29 (13) :1449-1451
[2]   Quantum non-Gaussianity of frequency up-converted single photons [J].
Baune, Christoph ;
Schoenbeck, Axel ;
Samblowski, Aiko ;
Fiurasek, Jaromir ;
Schnabel, Roman .
OPTICS EXPRESS, 2014, 22 (19) :22808-22816
[3]   PHOTOELECTRIC CORRELATION MEASUREMENTS WITH TIME-TO-AMPLITUDE CONVERTERS [J].
DAVIDSON, F ;
MANDEL, L .
JOURNAL OF APPLIED PHYSICS, 1968, 39 (01) :62-&
[4]   MEASUREMENTS OF PHOTON CORRELATIONS IN A LASER BEAM NEAR THRESHOLD WITH TIME-TO-AMPLITUDE CONVERTER TECHNIQUES [J].
DAVIDSON, F .
PHYSICAL REVIEW, 1969, 185 (02) :446-+
[5]   CORRELATIONS IN NONDEGENERATE PARAMETRIC OSCILLATION .2. BELOW THRESHOLD RESULTS [J].
DRUMMOND, PD ;
REID, MD .
PHYSICAL REVIEW A, 1990, 41 (07) :3930-3949
[6]   Implementation of a Nondeterministic Optical Noiseless Amplifier [J].
Ferreyrol, Franck ;
Barbieri, Marco ;
Blandino, Remi ;
Fossier, Simon ;
Tualle-Brouri, Rosa ;
Grangier, Philippe .
PHYSICAL REVIEW LETTERS, 2010, 104 (12)
[7]   Detecting Quantum States with a Positive Wigner Function beyond Mixtures of Gaussian States [J].
Filip, Radim ;
Mista, Ladislav, Jr. .
PHYSICAL REVIEW LETTERS, 2011, 106 (20)
[8]   NEW DIGITAL PHOTOELECTRIC CORRELATOR [J].
FRIBERG, S ;
ANDERSEN, J ;
MANDEL, L .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (02) :205-209
[9]   Detecting quantum non-Gaussianity via the Wigner function [J].
Genoni, Marco G. ;
Palma, Mattia L. ;
Tufarelli, Tommaso ;
Olivares, Stefano ;
Kim, M. S. ;
Paris, Matteo G. A. .
PHYSICAL REVIEW A, 2013, 87 (06)
[10]   EXPERIMENTAL-EVIDENCE FOR A PHOTON ANTICORRELATION EFFECT ON A BEAM SPLITTER - A NEW LIGHT ON SINGLE-PHOTON INTERFERENCES [J].
GRANGIER, P ;
ROGER, G ;
ASPECT, A .
EUROPHYSICS LETTERS, 1986, 1 (04) :173-179