A sensitive electrochemical protein quantification method

被引:0
作者
Schwarz, A [1 ]
Bagel, O [1 ]
Girault, HH [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Electrochim, CH-1015 Lausanne, Switzerland
关键词
protein assay; biuret reaction; electrochemical detection; copper;
D O I
10.1002/1521-4109(200007)12:11<811::AID-ELAN811>3.0.CO;2-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents a sensitive electrochemical method for the quantification of proteins. The assay used the biuret reaction, which is based on the complexation of proteins with copper ions to form a copper-protein complex. In the present approach, once copper ions were complexed with the protein, they were released by an acidic treatment and simultaneously separated by ultracentrifugation from the protein sample. This allowed differential pulse anodic stripping voltammetry (DPASV) of Cu2+ on carbon rotogravure printed electrodes (CARPEs). A nM detection limit for bovine serum albumin (BSA) was found with this method. The kinetics of this assay were tested and it resulted that the total assay can be carried out in 27 min, including incubation, washing steps and detection.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 25 条
[1]   A MODEL FOR FORMULATION OF PROTEIN ASSAY [J].
ALAM, A .
ANALYTICAL BIOCHEMISTRY, 1992, 203 (01) :121-126
[2]   Rotograved carbon electrodes for amperometric cadmium and lead determination [J].
Bagel, O ;
L'Hostis, E ;
Lagger, G ;
Osborne, MD ;
Seddon, BJ ;
Girault, HH ;
Brack, D ;
Loyall, U ;
Schäfer, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 469 (02) :189-195
[3]   Determination of sub-μg 1-1 concentrations of copper by anodic stripping voltammetry at the gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 1999, 387 (01) :85-95
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[5]  
COLIGAN JE, 1995, CURRENT PROTOCOLS PR, V1
[6]   DETERMINATION OF HEAVY-METALS IN REAL SAMPLES BY ANODIC-STRIPPING VOLTAMMETRY WITH MERCURY MICROELECTRODES .2. APPLICATION TO RAIN AND SEA WATERS [J].
DANIELE, S ;
BALDO, MA ;
UGO, P ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1989, 219 (01) :19-26
[7]  
DAVIS EM, 1988, AM BIOTECHNOL LAB, V6, P28
[8]   DETERMINATION OF PEPTIDES BY CAPILLARY ELECTROPHORESIS ELECTROCHEMICAL DETECTION USING ON-COLUMN CU(II) COMPLEXATION [J].
DEACON, M ;
OSHEA, TJ ;
LUNTE, SM ;
SMYTH, MR .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :377-383
[9]   HETEROGENEOUS IMMUNOASSAY FOR SERUM-PROTEINS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
DOYLE, MJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2318-2322
[10]   Determination of copper(II) by anodic stripping voltammetry using a flow-through system [J].
Economou, A ;
Fielden, PR .
ANALYST, 1996, 121 (12) :1903-1906