3D ultrasound guided navigation system with hybrid image fusion

被引:2
作者
Iommi, David [1 ]
Valladares, Alejandra [1 ]
Figl, Michael [1 ]
Grahovac, Marko [2 ]
Fichtinger, Gabor [3 ]
Hummel, Johann [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Spitalgasse 23, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Nucl Med, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[3] Queens Univ, Sch Comp, 25 Union St,557 Goodwin Hall, Kingston, ON K7L 3N6, Canada
关键词
REGISTRATION; MOTION;
D O I
10.1038/s41598-021-86848-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A prototype of a navigation system to fuse two image modalities is presented. The standard inter-modality registration is replaced with a tracker-based image registration of calibrated imaging devices. Intra-procedure transrectal US (TRUS) images were merged with pre-procedure magnetic resonance (MR) images for prostate biopsy. The registration between MR and TRUS images was performed by an additional abdominal 3D-US (ab-3D-US), which enables replacing the inter-modal MR/TRUS registration by an intra-modal ab-3D-US/3D-TRUS registration. Calibration procedures were carried out using an optical tracking system (OTS) for the pre-procedure image fusion of the ab-3D-US with the MR. Inter-modal ab-3D-US/MR image fusion was evaluated using a multi-cone phantom for the target registration error (TRE) and a prostate phantom for the Dice score and the Hausdorff distance of lesions . Finally, the pre-procedure ab- 3D-US was registered with the TRUS images and the errors for the transformation from the MR to the TRUS were determined. The TRE of the ab-3D-US/MR image registration was 1.81 mm. The Dice-score and the Hausdorff distance for ab-3D-US and MR were found to be 0.67 and 3.19 mm. The Dice score and the Hausdorff distance for TRUS and MR were 0.67 and 3.18 mm. The hybrid navigation system showed sufficient accuracy for fusion guided biopsy procedures with prostate phantoms. The system might provide intra-procedure fusion for most US-guided biopsy and ablation interventions.
引用
收藏
页数:10
相关论文
共 29 条
[11]   Weakly-supervised convolutional neural networks for multimodal image registration [J].
Hu, Yipeng ;
Modat, Marc ;
Gibson, Eli ;
Li, Wenqi ;
Ghavamia, Nooshin ;
Bonmati, Ester ;
Wang, Guotai ;
Bandula, Steven ;
Moore, Caroline M. ;
Emberton, Mark ;
Ourselin, Sebastien ;
Noble, J. Alison ;
Barratt, Dean C. ;
Vercauteren, Tom .
MEDICAL IMAGE ANALYSIS, 2018, 49 :1-13
[12]   Evaluation of a new electromagnetic tracking system using a standardized assessment protocol [J].
Hummel, J ;
Figl, M ;
Birkfellner, W ;
Bax, MR ;
Shahidi, R ;
Maurer, CR ;
Bergmann, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :N205-N210
[13]   Ultrasound Guidance System for Prostate Biopsy [J].
Hummel, Johann ;
Kerschner, Reinhard ;
Kaar, Marcus ;
Birkfellner, Wolfgang ;
Figl, Michael .
MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
[14]   Evaluation of 3D ultrasound for image guidance [J].
Iommi, David ;
Hummel, Johann ;
Figl, Michael Lutz .
PLOS ONE, 2020, 15 (03)
[15]   Automatic patient alignment system using 3D ultrasound [J].
Kaar, Marcus ;
Figl, Michael ;
Hoffmann, Rainer ;
Birkfellner, Wolfgang ;
Hummel, Johann ;
Stock, Markus ;
Georg, Dietmar ;
Goldner, Gregor .
MEDICAL PHYSICS, 2013, 40 (04)
[16]   PLUS: Open-Source Toolkit for Ultrasound-Guided Intervention Systems [J].
Lasso, Andras ;
Heffter, Tamas ;
Rankin, Adam ;
Pinter, Csaba ;
Ungi, Tamas ;
Fichtinger, Gabor .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (10) :2527-2537
[17]   Fusion imaging of real-time ultrasonography with CT or MRI for hepatic intervention [J].
Lee, Min Woo .
ULTRASONOGRAPHY, 2014, 33 (04) :227-239
[18]   Adversarial Learning for Deformable Image Registration: Application to 3D Ultrasound Image Fusion [J].
Li, Zisheng ;
Ogino, Masahiro .
SMART ULTRASOUND IMAGING AND PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, SUSI 2019, PIPPI 2019, 2019, 11798 :56-64
[19]  
Madabhushi A, 2013, SPIE MED IMAG, V8671
[20]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198