Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites?

被引:15
|
作者
Li, Junying [1 ,2 ]
Chen, Zhaozhao [1 ,2 ]
Chan, Hsun-Liang [1 ]
Sinjab, Khaled [1 ]
Yu, Haiyang [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Natl Clin Res Ctr Oral Dis,Dept Prosthodont, Chengdu, Sichuan, Peoples R China
关键词
computer-assisted; dental implants; flapless implant surgery; stereolithography; STEREOLITHOGRAPHIC SURGICAL GUIDES; COMPUTED-TOMOGRAPHY; SURGERY; TEMPLATES;
D O I
10.1111/cid.12847
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo investigate the effect of open-flap or flapless approaches on the accuracy of implant placement partially guided by tooth-supported surgical templates. Materials and MethodsA total of 36 edentulous sites were selected from seven human cadaver heads. Following the preoperative implant planning using Blue Sky Plan, surgical guides were fabricated by an in-office desktop 3D printer. All the sites were randomly divided into two groups: flapless approach (n = 18), and open-flap approach (n = 18). After guided osteotomy preparation with subsequent freehand implant placement, digital intraoral scanning was performed to obtain post-operative implant positions. Based on the image registration, the deviations between the planned and actual implant position were measured and compared. ResultsStatistically significant variance differences between the two approaches were found in the global coronal (open-flap: 0.860.23mm; flapless: 1.3 +/- 0.62mm; P<.001), global apical (open-flap: 1.38 +/- 0.37mm; flapless: 1.9 +/- 0.78mm; P = .002), and depth (open-flap: 0.59 +/- 0.34mm; flapless 0.89 +/- 0.78mm; P<.001) deviations. The differences were not significant regarding lateral (coronal and apical) and angular deviations. ConclusionsIn semi-guided implant surgery, the open-flap and flapless approaches demonstrate similar lateral and angular deviations. The open-flap group shows better depth control when manually inserting the implant.
引用
收藏
页码:1253 / 1261
页数:9
相关论文
共 41 条
  • [21] Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study
    Adams, Coleman R.
    Ammoun, Rami
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 62 - 70
  • [22] Accuracy of static computer-assisted implant placement in long span edentulous area by novice implant clinicians: A cross-sectional in vitro study comparing fully-guided, pilot-guided, and freehand implant placement protocols
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (03) : 361 - 372
  • [23] The accuracy of a partially guided system using an in-office 3D-printed surgical guide for implant placement
    Cho, Jin-yong
    Kim, Sung-beom
    Ryu, Jaeyoung
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (01) : 19 - 27
  • [24] Influence of the dental arch and number of cutting-off and rescanning mesh holes on the accuracy of implant scans in partially edentulous situations
    Gomez-Polo, Miguel
    Immorlano, Marina Garcia
    Cascos-Sanchez, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    JOURNAL OF DENTISTRY, 2023, 137
  • [25] Influence of clinical expertise and practical experience on transfer accuracy in guided dental implant placement - an in vitro study
    Reiff, Florian Sebastian
    Bischoff, Charlotte
    Woelfler, Henriette
    Roehling, Stefan
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 28 (04): : 1491 - 1500
  • [26] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [27] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [28] Does a fully digital workflow improve the accuracy of computer-assisted implant surgery in partially edentulous patients? A systematic review of clinical trials
    Siqueira, Rafael
    Chen, Zhaozhao
    Galli, Matthew
    Saleh, Islam
    Wang, Hom-Lay
    Chan, Hsun-Liang
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (06) : 660 - 671
  • [29] Influence of clinical and technical parameters on accuracy of guided implant placement. Systematic review and meta-analysis
    Kasradze, D.
    Segalyte, E.
    Kubilius, R.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 198 - 219
  • [30] Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols
    Jaafar Abduo
    Douglas Lau
    International Journal of Implant Dentistry, 6