Does flap opening or not influence the accuracy of semi-guided implant placement in partially edentulous sites?

被引:15
|
作者
Li, Junying [1 ,2 ]
Chen, Zhaozhao [1 ,2 ]
Chan, Hsun-Liang [1 ]
Sinjab, Khaled [1 ]
Yu, Haiyang [2 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Natl Clin Res Ctr Oral Dis,Dept Prosthodont, Chengdu, Sichuan, Peoples R China
关键词
computer-assisted; dental implants; flapless implant surgery; stereolithography; STEREOLITHOGRAPHIC SURGICAL GUIDES; COMPUTED-TOMOGRAPHY; SURGERY; TEMPLATES;
D O I
10.1111/cid.12847
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo investigate the effect of open-flap or flapless approaches on the accuracy of implant placement partially guided by tooth-supported surgical templates. Materials and MethodsA total of 36 edentulous sites were selected from seven human cadaver heads. Following the preoperative implant planning using Blue Sky Plan, surgical guides were fabricated by an in-office desktop 3D printer. All the sites were randomly divided into two groups: flapless approach (n = 18), and open-flap approach (n = 18). After guided osteotomy preparation with subsequent freehand implant placement, digital intraoral scanning was performed to obtain post-operative implant positions. Based on the image registration, the deviations between the planned and actual implant position were measured and compared. ResultsStatistically significant variance differences between the two approaches were found in the global coronal (open-flap: 0.860.23mm; flapless: 1.3 +/- 0.62mm; P<.001), global apical (open-flap: 1.38 +/- 0.37mm; flapless: 1.9 +/- 0.78mm; P = .002), and depth (open-flap: 0.59 +/- 0.34mm; flapless 0.89 +/- 0.78mm; P<.001) deviations. The differences were not significant regarding lateral (coronal and apical) and angular deviations. ConclusionsIn semi-guided implant surgery, the open-flap and flapless approaches demonstrate similar lateral and angular deviations. The open-flap group shows better depth control when manually inserting the implant.
引用
收藏
页码:1253 / 1261
页数:9
相关论文
共 41 条
  • [1] Does guided level (fully or partially) influence implant placement accuracy at post-extraction sockets and healed sites? An in vitro study
    Zhaozhao Chen
    Junying Li
    Priscila Ceolin Meneghetti
    Matthew Galli
    Gustavo Mendonça
    Hom-Lay Wang
    Clinical Oral Investigations, 2022, 26 : 5449 - 5458
  • [2] Does guided level (fully or partially) influence implant placement accuracy at post-extraction sockets and healed sites? An in vitro study
    Chen, Zhaozhao
    Li, Junying
    Meneghetti, Priscila Ceolin
    Galli, Matthew
    Mendonca, Gustavo
    Wang, Hom-Lay
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (08) : 5449 - 5458
  • [3] Clinical accuracy of partially guided implant placement in edentulous patients: A computed tomography-based retrospective study
    Wang, Baixiang
    Yang, Jiakang
    Siow, Lixuen
    Wang, Yu
    Zhang, Xinyue
    Zhou, Yiqun
    Yu, Mengfei
    Wang, Huiming
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, : 31 - 39
  • [4] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Gargallo-Albiol, Jordi
    Jose Zilleruelo-Pozo, Maria
    Lucas-Taule, Ernest
    Munoz-Penalver, Jesus
    Paternostro-Betancourt, Daniel
    Hernandez-Alfaro, Federico
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (03) : 2783 - 2791
  • [5] Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study
    Jordi Gargallo-Albiol
    María José Zilleruelo-Pozo
    Ernest Lucas-Taulé
    Jesús Muñoz-Peñalver
    Daniel Paternostro-Betancourt
    Federico Hernandez-Alfaro
    Clinical Oral Investigations, 2022, 26 : 2783 - 2791
  • [6] The influence of crown coverage on the accuracy of static guided implant surgery in partially edentulous models: An in vitro study
    Wang, Zhen-yu
    Chao, Jia-rui
    Zheng, Jia-wen
    You, Meng
    Liu, Yang
    Shen, Jie-fei
    JOURNAL OF DENTISTRY, 2021, 115
  • [7] An in vitro assessment of the accuracy of guided tilted and axial implant placement in the edentulous mandible
    Freeman, Brett C.
    Alqallaf, Hawra
    Yang, Chao-Chieh
    Lin, Wei-Shao
    Dutra, Vinicius
    Hamada, Yusuke
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [8] Clinical Accuracy of Flapless Computer-Guided Surgery for Implant Placement in Edentulous Arches
    Vieira, Dalton Marinho
    Sotto-Maior, Bruno Salles
    Villaca de Souza Barros, Carlos Alberto
    Reis, Elson Simoes
    Francischone, Carlos Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1347 - 1351
  • [9] Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol
    Marei, Hesham F.
    Abdel-Hady, Adel
    Al-Khalifa, Khalifa
    Al-Mahalawy, Haytham
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1173 - 1179
  • [10] Accuracy of computer-guided implant surgery in partially edentulous patients: a prospective observational study
    Chrabieh, Emile
    Hanna, Christine
    Mrad, Stephanie
    Rameh, Stephanie
    Bassil, Joseph
    Zaarour, Joseph
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)