N-Doped Hollow Porous Carbon Spheres/Bismuth Hybrid Film Modified Electrodes for Sensitive Voltammetric Determination of Trace Cadmium

被引:13
|
作者
Qin, Danfeng [1 ]
Wang, Le [1 ]
Gao, Sanshuang [1 ]
Wang, Ying [1 ,4 ]
Mamat, Xamxikamar [1 ]
Li, Yongtao [1 ]
Wagberg, Thomas [2 ]
Cheng, Hao [3 ]
Hu, Guangzhi [1 ,2 ]
机构
[1] Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, State Key Lab Basis Xinjiang Indigenous Med Plant, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
[2] Umea Univ, Dept Phys, S-90187 Umea, Sweden
[3] Guangxi Univ Sci & Technol, Guangxi Key Lab Green Proc Sugar Resources, Liuzhou 545006, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
N-doped hollow porous carbon spheres; bismuth film; differential pulse anodic stripping voltammetry; cadmium; tap water; lake water; ANODIC-STRIPPING VOLTAMMETRY; HIGH-PERFORMANCE SUPERCAPACITORS; ELECTROCHEMICAL DETECTION; MESOPOROUS CARBON; SPHERES; CD(II); PB(II); REDUCTION; BATTERIES; GRAPHENE;
D O I
10.1002/elan.201700839
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, N-doped hollow porous carbon spheres (N-HPCSs) were synthesized by silicon dioxide template-assisted polybenzoxazine (PB) coating strategy. The prepared N-HPCSs have a smooth hollow ball structure surrounded by a well-defined porous shell. Combining with in-situ plating of Bi film, the N-HPCSs were further fabricated a sensitive electrochemical platform for determination trace levels of Cd(II) by differential pulse anodic stripping voltammetry (DPASV). Under the optimized conditions, the Bi-N-HPCSs based sensor displays a linear response to Cd(II) over the range of 0.5gL(-1) to 150gL(-1). Meanwhile, the limit of detection (LOD, S/N=3) is estimated to be around 0.16gL(-1) for Cd(II), which is 31 times lower than the safety values set by United States Environmental Protection Agency (EPA) for the drinking water. Moreover, the proposed method was successfully applied to detection of Cd(II) in tap water and lake water, and the analytical results of the presented method are agreed well with inductively coupled plasma-mass spectrometry (ICP-MS) data. Due to the excellent analytical performance, the fabricated electrode is promised for future development in monitoring of cadmium pollution in the environment.
引用
收藏
页码:1906 / 1912
页数:7
相关论文
共 50 条
  • [1] Determination of Zinc and Cadmium with Characterized Electrodes of Carbon and Polyurethane Modified by a Bismuth Film
    Brasil Bernardelli, Jossy Karla
    Lapolli, Flavio Rubens
    Gomes da Silva Cruz, Carlos Marcus
    Floriano, Joao Batista
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2011, 14 (03): : 366 - 371
  • [2] Fe/N-doped hollow porous carbon spheres for oxygen reduction reaction
    Wang, Siyu
    Chen, Lulu
    Liu, Xiangjian
    Long, Ling
    Liu, Haohui
    Liu, Changyu
    Dong, Shaojun
    Jia, Jianbo
    NANOTECHNOLOGY, 2020, 31 (12)
  • [3] A Voltammetric Approach for the Simultaneous Determination of Cd and Pb in Water Applying Carbon Paste Electrode Modified with Bismuth Film
    de Oliveira, Cristiane
    Maciel, Juliana Villela
    Christ-Ribeiro, Anelise
    Guarda, Ananda
    Dias, Daiane
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (03) : 369 - 375
  • [4] A novel N-doped porous carbon microsphere composed of hollow carbon nanospheres
    Zhang, Jiangru
    Wang, Xiang
    Qi, Guicun
    Li, Binghai
    Song, Zhihai
    Jiang, Haibin
    Zhang, Xiaohong
    Qiao, Jinliang
    CARBON, 2016, 96 : 864 - 870
  • [5] A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants
    Chamjangali, M. Arab
    Kouhestani, H.
    Masdarolomoor, F.
    Daneshinejad, H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 384 - 393
  • [6] Sensitive determination of Cd(II) by square wave anodic stripping voltammetry with in situ bismuth-modified multiwalled carbon nanotubes doped carbon paste electrodes
    Luo, Jun Hua
    Jiao, Xiao Xia
    Li, Nian Bing
    Luo, Hong Qun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 130 - 134
  • [7] Anodic stripping voltammetric measurement of trace cadmium at antimony film modified sodium montmorillonite doped carbon paste electrode
    Chen, Guo
    Hao, Xia
    Li, Bang Lin
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 : 570 - 574
  • [8] From Hollow Carbon Spheres to N-Doped Hollow Porous Carbon Bowls: Rational Design of Hollow Carbon Host for Li-S Batteries
    Pei, Fei
    An, Taihua
    Zang, Jun
    Zhao, Xiaojing
    Fang, Xiaoliang
    Zheng, Minseng
    Dong, Quanfeng
    Zheng, Nanfeng
    ADVANCED ENERGY MATERIALS, 2016, 6 (08)
  • [9] Trace level voltammetric determination of lead and cadmium in sediment pore water by a bismuth-oxychloride particle-multiwalled carbon nanotube composite modified glassy carbon electrode
    Cerovac, Sandra
    Guzsvany, Valeria
    Konya, Zoltan
    Ashrafi, Amir M.
    Svancara, Ivan
    Roncevic, Srdan
    Kukovecz, Akos
    Dalmacija, Bozo
    Vytras, Karel
    TALANTA, 2015, 134 : 640 - 649
  • [10] High Sensitivity and Reproducibility of a Bismuth/Poly(bromocresol purple) Film Modified Glassy Carbon Electrode for Determination of Trace Amount of Cadmium by Differential Pulse Anodic Stripping Voltammetry
    Yang, Gongjun
    Yan, Jiankang
    Qi, Fen
    Sun, Cheng
    ELECTROANALYSIS, 2010, 22 (22) : 2729 - 2738