Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study

被引:31
|
作者
Arnholt, Christina M. [1 ]
MacDonald, Daniel W. [1 ]
Underwood, Richard J. [2 ]
Guyer, Eric P. [3 ]
Rimnac, Clare M. [4 ]
Kurtz, Steven M. [1 ,2 ]
Mont, Michael A. [5 ]
Klein, Gregg R. [6 ]
Lee, Gwo-Chin [7 ]
Chen, Antonia F. [8 ]
Hamlin, Brian R. [9 ]
Cates, Harold E. [10 ]
Malkani, Arthur L. [11 ,12 ]
Kraay, Matthew J. [4 ]
机构
[1] Drexel Univ, Implant Res Ctr, 3401 Market St,Suite 345, Philadelphia, PA 19104 USA
[2] Exponent Inc, Philadelphia, PA USA
[3] Exponent Inc, Atlanta, GA USA
[4] Case Western Reserve Univ, Ctr Evaluat Implant Performance, Cleveland, OH 44106 USA
[5] Sinai Hosp Baltimore, Baltimore, MD USA
[6] Hartzband Ctr Hip & Knee Replacement, Paramus, NJ USA
[7] Univ Penn Hlth Syst, Presbyterian Med Ctr, Philadelphia, PA USA
[8] Thomas Jefferson Univ Hosp, Rothman Inst, Philadelphia, PA 19107 USA
[9] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
[10] Tennessee Orthopaed Clin, Knoxville, TN USA
[11] Jewish Hosp, Louisville, KY USA
[12] St Marys Hlth Care, Louisville, KY USA
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
mechanically assisted crevice corrosion; fretting; corrosion; taper; microgrooves; ON-METAL BEARINGS; SURFACE-TOPOGRAPHY; FAILURE; NECK; REPLACEMENTS; MODULARITY; TRUNNIONS; IMPLANTS; JUNCTION; WEAR;
D O I
10.1016/j.arth.2016.11.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. Methods: A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Results: Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. Conclusion: The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1363 / 1373
页数:11
相关论文
共 50 条
  • [21] Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty
    Kwon, Young-Min
    Tsai, Tsung-Yuan
    Leone, William A.
    Liow, Ming Han Lincoln
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03): : 996 - 1000
  • [22] The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty
    Krull, Annika
    Morlock, Michael M.
    Bishop, Nicholas E.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3200 - 3205
  • [23] Modular Taper Junction Corrosion and Failure: How to Approach a Recalled Total Hip Arthroplasty Implant
    Pivec, Robert
    Meneghini, R. Michael
    Hozack, William J.
    Westrich, Geoffrey H.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 1 - 6
  • [24] A novel method to improve femoral head and stem taper stability intraoperatively in total hip arthroplasty - a proof of concept study
    Dun, Shouchen
    Lim, Boon Him
    Swope, Stephen W.
    Whitaker, Dustin R.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (08)
  • [25] Effect of surface topography and residual stress on the taper connection stability in total hip arthroplasty
    Mai, Phuong Thao
    Bormann, Therese
    Mueller, Ulrike
    Kretzer, Jan Philippe
    Gibmeier, Jens
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128
  • [26] Gross Taper Failure and Fracture of the True Neck in Total Hip Arthroplasty: Retrieval Scanning Electron Microscope Analysis
    Ciatti, Corrado
    Moschella, Michelangelo
    Bori, Edoardo
    Doria, Carlo
    Caggiari, Gianfilippo
    Innocenti, Bernardo
    Pisanu, Francesco
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [27] Nontribological corrosion modes dominate wrought CoCrMo acetabular taper corrosion: A retrieval study
    Shenoy, Aarti A.
    Kurtz, Steven M.
    Gilbert, Jeremy L.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2021, 109 (12) : 2000 - 2013
  • [28] Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty: An in vitro study
    Bormann, Therese
    Nebel, Laura
    Mueller, Ulrike
    Mai, Phuong Thao
    Gibmeier, Jens
    Renkawitz, Tobias
    Kretzer, J. Philippe
    ACTA BIOMATERIALIA, 2022, 145 : 427 - 435
  • [29] Corrosion on the Acetabular Liner Taper from Retrieved Modular Metal-on-Metal Total Hip Replacements
    Gascoyne, Trevor C.
    Dyrkacz, Richard M.
    Turgeon, Thomas R.
    Burnell, Colin D.
    Wyss, Urs P.
    Brandt, Jan-M.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (10): : 2049 - 2052
  • [30] Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty
    Cooper, H. John
    Della Valle, Craig J.
    Berger, Richard A.
    Tetreault, Matthew
    Paprosky, Wayne G.
    Sporer, Scott M.
    Jacobs, Joshua J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18): : 1655 - 1661