Skin-Induced Motion Artifact Removal for Ambulatory Electrocardiography

被引:3
|
作者
He, Zhuobiao [1 ]
Min, Hao [1 ]
机构
[1] Fudan Univ, Inst Microelect, Shanghai 200433, Peoples R China
关键词
ECG; electrode-tissue impedance; LMS algorithm; motion artifacts; reference signal; skin impedance; skin-induced motion artifact; time constant; REDUCTION; ECG;
D O I
10.1109/JSEN.2022.3186301
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Skin-induced motion artifact ( SIMA) is a troublesome problem for ambulatory electrocardiography (ECG) signal acquisition by e-skin dry sensor. Reference based algorithm is a promising way to tackle it. A highly correlated reference signal is the key for this solution. In this article, by using a new synthesized reference signal for LMS algorithm, which combines both skin induced impedance behavior and skin "slope" and recovery "time constant", the SIMA related noise is greatly reduced. Firstly, we show the phenomenon that the SIMA "slope" and "recovery time constant" have some relationshipswith skin induced impedance, its derivatives and specific tissue characteristics. Secondly, We do the offline "slope" and "time constant" calibrationwork first, then measure the real time skin induced impedance, and then combine the above information together, to form a virtual reference signal, then we show the new reference has high correlation with actual SIMA noise. Finally, considering that SIMA potential consists of fast changing part and slow changing part, we use an improved LMS algorithm to handle the contradiction between speed and accuracy, which includes fast tracking part and low convergence error part. We set up the SIMA removal system in Matlab, and use actual motion artifact contaminated ECG signal as the input, and then do offline signal processing. Results show that SIMA is improved around 7 similar to 15dB typically on average. Integrating skin-induced impedancewith human body related "slope" and "time constant" as a reference signal seems a feasible method to remove skin-inducedmotion artifact.
引用
收藏
页码:15033 / 15043
页数:11
相关论文
共 50 条
  • [1] Motion Artifact Reduction in Ambulatory Electrocardiography using Inertial Measurement Units and Kalman Filtering
    Hostettler, Roland
    Lumikari, Tuomas
    Palva, Lauri
    Nieminen, Tuomo
    Sarkka, Simo
    2018 21ST INTERNATIONAL CONFERENCE ON INFORMATION FUSION (FUSION), 2018, : 780 - 787
  • [2] Motion Artifact Removal Based on ICA for Ambulatory ECG Monitoring
    Tian, Shudong
    Han, Jun
    Yang, Jianwei
    Zhou, Lijun
    Zeng, Xiaoyang
    PROCEEDINGS OF 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2015,
  • [3] Fish skin-induced dermatitis
    Weinberg, JM
    Haimowitz, JE
    Spiers, EM
    Mowad, C
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2000, 14 (03) : 222 - 223
  • [4] Real-time Motion Artifact Detection and Removal for Ambulatory BCI
    Kim, Byung Hyung
    Jo, Sungho
    3RD INTERNATIONAL WINTER CONFERENCE ON BRAIN-COMPUTER INTERFACE, 2015, : 70 - 73
  • [5] Motion Artifact in Ambulatory Electrocardiogram
    Zhao, Jian-Long (jlzhao@mail.sim.ac.cn), 2017, South China University of Technology (45):
  • [6] A Multi-Channel Electrode Tissue Impedance Detection Approach for Motion Artifact Suppression in Ambulatory Electrocardiography
    Zhang, Huanqian
    Zhang, Shulin
    Du, Xiaowei
    Tao, Ruojie
    Jin, Qinghui
    Li, Qing
    Yang, Jian
    Zhao, Jianlong
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 117 - 120
  • [7] Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis
    Berwal, Deepak
    Vandana, C. R.
    Dewan, Sourya
    Jiji, C., V
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2019, 19 (24) : 12432 - 12442
  • [8] Motion Artifact Removal using Cascade Adaptive Filtering for Ambulatory ECG Monitoring System
    Kim, Hyejung
    Kim, Sunyoung
    Van Helleputte, Nick
    Berset, Torfinn
    Geng, Di
    Romero, Inaki
    Penders, Julien
    Van Hoof, Chris
    Yazicioglu, Refet Firat
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 160 - 163
  • [9] Adaptive removal of motion artifact
    Hamilton, PS
    Curley, MG
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 297 - 299
  • [10] Langerhans cells are crucial in the skin-induced tolerance to peanut
    Yu, X.
    Chen, T.
    Feng, H.
    Tian, Y.
    Yao, X.
    Li, W.
    ALLERGY, 2014, 69 : 85 - 86