Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices

被引:48
作者
DeRose, JJ
Umana, JP
Argenziano, M
Catanese, KA
Levin, HR
Sun, BC
Rose, EA
Oz, MC
机构
[1] Columbia Presbyterian Med Ctr, Div Cardiothorac Surg, New York, NY 10032 USA
[2] Columbia Presbyterian Med Ctr, Div Circulatory Physiol, New York, NY 10032 USA
关键词
D O I
10.1016/S0003-4975(97)01107-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Over the past decade, the use of mechanical circulatory support in patients with postcardiotomy cardiogenic shock has resulted in hospital discharge rates of 25% to 40%. In an attempt to improve patient survival, we initiated a program of early insertion of an implantable Thermocardiosystems Incorporated Heartmate left ventricular assist device in patients who have circulatory failure after having undergone high-risk cardiac operations. Methods. Between April 1993 and February 1997, 12 patients underwent insertion of an implantable left ventricular assist device for postcardiotomy cardiogenic shock after coronary artery bypass grafting. Indications for insertion included postoperative cardiogenic shock (7 patients), postoperative cardiac arrest (3 patients), and failure to wean from cardiopulmonary bypass (2 patients). Results. The median time to device insertion was 3.5 days. The mean duration of left ventricular assist device support was 103 +/- 19 days (range, 2 to 225 days). Nine of 11 patients (82%) survived to undergo either transplantation (8 patients) or explantation (1 patient), with successful hospital discharge of all 9 patients. The major complication was device-related infection (42%). A single thromboembolism occurred in a patient with an infection. Conclusions. Long-term outcome after postcardiotomy cardiogenic shock is improved substantially with the use of an implantable left ventricular assist device early in the postoperative course. Access to such a device is an important consideration before undertaking a high-risk cardiac operation, and early implantation of the device is a critical factor in ensuring long-term survival. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:1757 / 1762
页数:6
相关论文
共 23 条
[1]   EFFECT OF CIRCULATORY ASSIST DEVICES ON STUNNED MYOCARDIUM [J].
BAVARIA, JE ;
FURUKAWA, S ;
KREINER, G ;
GUPTA, KB ;
STREICHER, J ;
EDMUNDS, LH .
ANNALS OF THORACIC SURGERY, 1990, 49 (01) :123-128
[2]   Outpatient left ventricular assist device support: A destination rather than a bridge [J].
Catanese, KA ;
Goldstein, DJ ;
Williams, DL ;
Foray, AT ;
Illick, CD ;
Gardocki, MT ;
Weinberg, AD ;
Levin, HR ;
Rose, EA ;
Oz, MC .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :646-652
[3]   Use of centrifugal pumps for postcardiotomy ventricular failure: Technique and anticoagulation [J].
Curtis, JJ ;
Walls, JT ;
Schmaltz, RA ;
Demmy, TL ;
WagnerMann, CC ;
McKenney, CA .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :296-300
[4]   IMPROVING CLINICAL OUTCOME WITH CENTRIFUGAL MECHANICAL ASSIST FOR POSTCARDIOTOMY VENTRICULAR FAILURE [J].
CURTIS, JJ ;
WALLS, JT ;
SCHMALTZ, RA ;
DEMMY, TL ;
WAGNERMANN, C ;
MCKENNEY, C ;
NAWARAWONG, W .
ARTIFICIAL ORGANS, 1995, 19 (07) :761-765
[5]  
DOWNING TP, 1986, J THORAC CARDIOV SUR, V92, P210
[6]   USE OF APROTININ IN LVAD RECIPIENTS REDUCES BLOOD-LOSS, BLOOD USE, AND PERIOPERATIVE MORTALITY [J].
GOLDSTEIN, DJ ;
SELDOMRIDGE, JA ;
CHEN, JM ;
CATANESE, KA ;
DEROSA, CM ;
WEINBERG, AD ;
SMITH, CR ;
ROSE, EA ;
LEVIN, HR ;
OZ, MC .
ANNALS OF THORACIC SURGERY, 1995, 59 (05) :1063-1068
[7]   ABIOMED BVS 5000: Experience and potential advantages [J].
Jett, GK .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :301-304
[8]   Mechanical circulatory support with the thoratec assist device in patients with postcardiotomy cardiogenic shock [J].
Korfer, R ;
ElBanayosy, A ;
Posival, H ;
Minami, K ;
Kizner, L ;
Arusoglu, L ;
Korner, MM .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :314-316
[9]  
MCENANY TM, 1978, CIRCULATION 2, V58, P1124
[10]  
Morrone TM, 1996, J HEART LUNG TRANSPL, V15, P423