Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution

被引:13
|
作者
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Ismail, Tevfik F. [1 ]
Neji, Radhouene [1 ,2 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Dept Biomed Engn, London, England
[2] Siemens Healthcare, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
fast imaging; isotropic resolution; motion correction; myocardial T-2 mapping; T-2; quantification; SATURATION-RECOVERY; MYOCARDIAL T-1; T2; T1; QUANTIFICATION; ANGIOGRAPHY; ACCURACY;
D O I
10.1002/mrm.27989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To enable free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion-corrected undersampled signal matched (MUST) T-2 map is achieved by combining an undersampled motion-compensated T-2-prepared Cartesian acquisition with a high-order patch-based reconstruction. Methods The 3D MUST-T-2 mapping acquisition consists of an electrocardiogram-triggered, T-2-prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T-2-weighted volumes are acquired using a 3D Cartesian variable-density sampling with increasing T-2 preparation times. A 2D image-based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high-dimensionality undersampled patch-based reconstruction is used in concert with dictionary matching to generate 3D T-2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5-mm(3) isotropic resolution. Three-dimensional MUST-T-2 was compared against standard multi-echo spin-echo sequence (phantom) and conventional breath-held single-shot 2D SSFP T-2 mapping (in vivo). Results Three-dimensional MUST-T-2 showed high accuracy in phantom experiments (R-2 > 0.99). The precision of T-2 values was similar for 3D MUST-T-2 and 2D balanced SSFP T-2 mapping in vivo (5 +/- 1 ms versus 4 +/- 2 ms, P = .52). Slightly longer T-2 values were observed with 3D MUST-T-2 in comparison to 2D balanced SSFP T-2 mapping (50.7 +/- 2 ms versus 48.2 +/- 1 ms, P < .05). Preliminary results in patients demonstrated T-2 values in agreement with literature values. Conclusion The proposed approach enables free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T-2 quantification of myocardial tissue in a clinically feasible scan time.
引用
收藏
页码:988 / 1002
页数:15
相关论文
共 50 条
  • [31] Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping
    Qi, Haikun
    Bustin, Aurelien
    Kuestner, Thomas
    Hajhosseiny, Reza
    Cruz, Gastao
    Kunze, Karl
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [32] Non-contrast free-breathing whole-heart 3D cine cardiovascular magnetic resonance with a novel 3D radial leaf trajectory
    Braunstorfer, Lukas
    Romanowicz, Jennifer
    Powell, Andrew J.
    Pattee, Jack
    Browne, Lorna P.
    van der Geest, Rob J.
    Moghari, Mehdi H.
    MAGNETIC RESONANCE IMAGING, 2022, 94 : 64 - 72
  • [33] Free-Breathing 3 T Magnetic Resonance T2-Mapping of the Heart
    van Heeswijk, Ruud B.
    Feliciano, Helene
    Bongard, Cedric
    Bonanno, Gabriele
    Coppo, Simone
    Lauriers, Nathalie
    Locca, Didier
    Schwitter, Juerg
    Stuber, Matthias
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (12) : 1231 - 1239
  • [34] Free-running 3D whole heart myocardial T1 mapping with isotropic spatial resolution
    Qi, Haikun
    Jaubert, Olivier
    Bustin, Aurelien
    Cruz, Gastao
    Chen, Huijun
    Botnar, Rene
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1331 - 1342
  • [35] 3D whole-heart isotropic-resolution motion-compensated joint T1/T2mapping and water/fat imaging
    Milotta, Giorgia
    Bustin, Aurelien
    Jaubert, Olivier
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3009 - 3026
  • [36] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Pennig, Lenhard
    Lennartz, Simon
    Wagner, Anton
    Sokolowski, Marcel
    Gajzler, Matej
    Ney, Svenja
    Laukamp, Kai Roman
    Persigehl, Thorsten
    Bunck, Alexander Christian
    Maintz, David
    Weiss, Kilian
    Naehle, Claas Philip
    Doerner, Jonas
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [37] Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease
    Fotaki, Anastasia
    Pushparajah, Kuberan
    Rush, Christopher
    Munoz, Camila
    Velasco, Carlos
    Neji, Radhouene
    Kunze, Karl P.
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [38] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Lenhard Pennig
    Simon Lennartz
    Anton Wagner
    Marcel Sokolowski
    Matej Gajzler
    Svenja Ney
    Kai Roman Laukamp
    Thorsten Persigehl
    Alexander Christian Bunck
    David Maintz
    Kilian Weiss
    Claas Philip Naehle
    Jonas Doerner
    Journal of Cardiovascular Magnetic Resonance, 22
  • [39] An Efficient Multi-resolution Reconstruction Scheme with Motion Compensation for 5D Free-Breathing Whole-Heart MRI
    Menchon-Lara, Rosa-Maria
    Royuela-del-Val, Javier
    Godino-Moya, Alejandro
    Cordero-Grande, Lucilio
    Simmross-Wattenberg, Federico
    Martin-Fernandez, Marcos
    Alberola-Lopez, Carlos
    MOLECULAR IMAGING, RECONSTRUCTION AND ANALYSIS OF MOVING BODY ORGANS, AND STROKE IMAGING AND TREATMENT, 2017, 10555 : 136 - 145
  • [40] Free-Breathing, Motion-Corrected, Highly Efficient Whole Heart T2 Mapping at 3T with Hybrid Radial-Cartesian Trajectory
    Yang, Hsin-Jung
    Sharif, Behzad
    Pang, Jianing
    Kali, Avinash
    Bi, Xiaoming
    Cokic, Ivan
    Li, Debiao
    Dharmakumar, Rohan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 126 - 136