Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy

被引:20
作者
Elcim, Yelda [1 ]
Dirican, Bahar [1 ]
Yavas, Omer [2 ]
机构
[1] Gulhane Training & Res Hosp, Dept Radiat Oncol, Ankara, Turkey
[2] Ankara Univ, Dept Engn Phys, Ankara, Turkey
关键词
algorithm; Monte Carlo; pencil beam; radiotherapy; treatment planning systems; DOSE CALCULATION;
D O I
10.1002/acm2.12426
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study, lung radiotherapy target volumes as well as critical organs such as the lungs, spinal cord, esophagus, and heart doses calculated using pencil beam (PB) and Monte Carlo (MC) algorithm-based treatment planning systems (TPSs) were compared. The main aim was the evaluation of calculated dose differences between the PB and MC algorithms in a highly heterogeneous medium. Methods: A total of 6 MV photon energy conformal treatment plans were created for a RANDO lung phantom using one PB algorithm-based Precise Plan Release 2.16 TPS and one MC algorithm-based Monaco TPS. Thermoluminescence dosimeters (TLDs) were placed into appropriate slices within the RANDO phantom and then irradiated with an Elekta-Synergy (R) Linear Accelerator for dose verification. Doses were calculated for the V5, V10, V20, and mean lung doses (MLDs) in bilateral lungs and D50, D98, D2, and mean doses in the target volume (planning target volume, PTV). Results: The minimum, maximum, and mean doses of the target volumes and critical organs in two treatment plans were compared using dose volume histograms (DVHs). The mean dose difference between the PB and MC algorithms for the PTV was 0.3%, whereas the differences in V5, V10, V20, and MLD were 12.5%, 15.8%, 14.4%, and 9.1%, respectively. The differences in PTV coverage between the two algorithms were 0.9%, 2.7% and 0.7% for D50, D98 and D2, respectively. Conclusions: A comparison of the dose data acquired in this study reveals that the MC algorithm calculations are closer to the 60 Gy prescribed dose for PTV, while the difference between the PB and MC algorithms was found to be non-significant. Because of the major difference arising from the dose calculation techniques by TPS that was observed in the MLD with significant medium heterogeneity, we recommend the use of the MC algorithm in such heterogeneous sites.
引用
收藏
页码:616 / 624
页数:9
相关论文
共 24 条
[1]  
*AAPM, 2004, 85 AAPM
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]  
[Anonymous], 2009, TG142 AAPM
[4]   Clinical implications in the use of the PBC algorithm versus the AAA by comparison of different NTCP models/parameters [J].
Bufacchi, Antonella ;
Nardiello, Barbara ;
Capparella, Roberto ;
Begnozzi, Luisa .
RADIATION ONCOLOGY, 2013, 8
[5]  
Carolan GM, 2010, PENCIL BEAM DOSE CAL
[6]   Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium [J].
Carrasco, P ;
Jornet, N ;
Duch, MA ;
Weber, L ;
Ginjaume, M ;
Eudaldo, T ;
Jurado, D ;
Ruiz, A ;
Ribas, M .
MEDICAL PHYSICS, 2004, 31 (10) :2899-2911
[7]   Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue [J].
De Jaeger, K ;
Hoogeman, MS ;
Engelsman, M ;
Seppenwoolde, Y ;
Damen, EMF ;
Mijnheer, BJ ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (01) :1-10
[8]   An in-depth Monte Carlo study of lateral electron disequilibrium for small fields in ultra-low density lung: implications for modern radiation therapy [J].
Disher, Brandon ;
Hajdok, George ;
Gaede, Stewart ;
Battista, Jerry J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (06) :1543-1559
[9]  
Dorje T, 2014, J CANC TREAT RES, V2, P1
[10]   Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours [J].
Engelsman, M ;
Damen, EMF ;
Koken, PW ;
van 't Veld, AA ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :299-309