Characterization of a micromachined planar patch clamp for cellular electrophysiology

被引:8
作者
Matthews, B [1 ]
Judy, JW [1 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
来源
1ST INTERNATIONAL IEEE EMBS CONFERENCE ON NEURAL ENGINEERING 2003, CONFERENCE PROCEEDINGS | 2003年
关键词
patch-clamp; micromachining; MEMS; electrophysiology;
D O I
10.1109/CNE.2003.1196912
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We have fabricated planar patch-clamp substrates suitable for use in cellular electrophysiology. The substrates are a base component of a larger automated dose-response measurement system. Substrates with cell-patch-site apertures ranging from 0.5 mum to 11 mum were fabricated using standard MEMS techniques. The resistance of the cell-patch-site apertures and substrate capacitance were measured using impedance spectroscopy. The resistance of the cell-patch sites ranged from 0.2 MOmega to 47 MOmega for apertures ranging from 12 mum to 0.75 mum. The substrate capacitance was 17.2 pF per mm(2) of fluid contact area for substrates with a 2-mum thick layer of silicon dioxide. It was found that the electrical properties of the substrates are acceptable for use in electrophysiological applications.
引用
收藏
页码:648 / 651
页数:4
相关论文
共 10 条
  • [1] Individually addressable planar patch clamp array
    Cheung, K
    Kubow, T
    Lee, LP
    [J]. 2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, : 71 - 75
  • [2] *CLAR LTD, 2000, DAT SHEET AZ5200 SER
  • [3] Fertig N, 2001, BIOPHYS J, V80, p337A
  • [4] Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells
    Klemic, KG
    Klemic, JF
    Reed, MA
    Sigworth, FJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 597 - 604
  • [5] SINGLE-CHANNEL CURRENTS RECORDED FROM MEMBRANE OF DENERVATED FROG MUSCLE-FIBERS
    NEHER, E
    SAKMANN, B
    [J]. NATURE, 1976, 260 (5554) : 799 - 802
  • [6] Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip
    Pantoja, R
    Sigg, D
    Blunck, R
    Bezanilla, F
    Heath, JR
    [J]. BIOPHYSICAL JOURNAL, 2001, 81 (04) : 2389 - 2394
  • [7] SAKMANN B, 1983, SINGLE CHANNEL RECOR
  • [8] Schmidt C, 2000, ANGEW CHEM INT EDIT, V39, P3137, DOI 10.1002/1521-3773(20000901)39:17<3137::AID-ANIE3137>3.0.CO
  • [9] 2-D
  • [10] Robust, high-resolution, whole cell patch-clamp capacitance measurements using square wave stimulation
    Thompson, RE
    Lindau, M
    Webb, WW
    [J]. BIOPHYSICAL JOURNAL, 2001, 81 (02) : 937 - 948