Comparison of blood-culture contamination rates in a pediatric emergency room: Newly inserted intravenous catheters versus venipuncture

被引:36
作者
Ramsook, C
Childers, K
Cron, SG
Nirken, M
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat, Sect Emergency Med, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat, Sect Acad Gen Pediat, Houston, TX 77030 USA
关键词
D O I
10.1086/501708
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We compared contamination rates of blood cultures obtained either from newly inserted intravenous catheters or via venipuncture. Of 2,431 blood cultures, the overall contamination rate was 2.7% (intravenous catheter, 3.4%; venipuncture, 2.0%; P=.043). The site of lowest contamination was the antecubital fossa, making this the optimal choice for blood-culture sampling (Infect Control Hosp Epidemiol 2000;21:649-651).
引用
收藏
页码:649 / 651
页数:3
相关论文
共 9 条
  • [1] RELIABILITY OF BLOOD CULTURES COLLECTED FROM INTRAVASCULAR CATHETER VERSUS VENIPUNCTURE
    BRYANT, JK
    STRAND, CL
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (01) : 113 - 116
  • [2] UTILITY OF COLLECTING BLOOD CULTURES THROUGH NEWLY INSERTED INTRAVENOUS CATHETERS
    ISAACMAN, DJ
    KARASIC, RB
    [J]. PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1990, 9 (11) : 815 - 818
  • [3] PSEUDOBACTERAEMIA
    JUMAA, PA
    CHATTOPADHYAY, B
    [J]. JOURNAL OF HOSPITAL INFECTION, 1994, 27 (03) : 167 - 177
  • [4] BLOOD CULTURE PHLEBOTOMY - SWITCHING NEEDLES DOES NOT PREVENT CONTAMINATION
    KRUMHOLZ, HM
    CUMMINGS, S
    YORK, M
    [J]. ANNALS OF INTERNAL MEDICINE, 1990, 113 (04) : 290 - 292
  • [5] Intravenous catheter blood cultures: Utility and contamination
    McQuillen, KK
    Santucci, KA
    Conrad, MA
    Nelson, DG
    Lewander, W
    Duffy, SJ
    Anderson, AC
    [J]. PEDIATRICS, 1999, 103 (04) : art. no. - e52
  • [6] THE EFFECT OF SKIN DISINFECTION MATERIALS ON REDUCING BLOOD CULTURE CONTAMINATION
    SCHIFMAN, RB
    PINDUR, A
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (05) : 536 - 538
  • [7] EFFECT OF NEEDLE CHANGING AND INTRAVENOUS CANNULA COLLECTION ON BLOOD CULTURE CONTAMINATION RATES
    SMART, D
    BAGGOLEY, C
    HEAD, J
    NOBLE, D
    WETHERALL, B
    GORDON, DL
    [J]. ANNALS OF EMERGENCY MEDICINE, 1993, 22 (07) : 1164 - 1168
  • [8] EFFECT OF LODOPHOR VS IODINE TINCTURE SKIN PREPARATION ON BLOOD CULTURE CONTAMINATION RATE
    STRAND, CL
    WAJSBORT, RR
    STURMANN, K
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (08): : 1004 - 1006
  • [9] Doing it right the first time: Quality improvement and the contaminant blood culture
    Weinbaum, FI
    Lavie, S
    Danek, M
    Sixsmith, D
    Heinrich, GF
    Mills, SS
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (03) : 563 - 565