Functional vision after cataract removal with multifocal and accommodating intraocular lens implantation -: Prospective comparative evaluation of array multifocal and 1CU accommodating lenses

被引:24
作者
Claoué, C
机构
[1] Hartswood Hospital, Brentwood
[2] PO Box 12650, London SE3 9ZZ, GBR
关键词
D O I
10.1016/j.jcrs.2004.05.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the efficacy (functional vision, spectacle dependence) of the Array(R) multifocal intraocular lens (IOL) (Advanced Medical Optics) and the 1CU accommodating IOL (HumanOptics AG). Setting: Hartswood Hospital, Brentwood, United Kingdom. Methods: This prospective study comprised patients scheduled to have standard phacoemulsification surgery with IOL implantation. Patients expressing a preference for spectacle independence were allocated to the Array multifocal IOL group. Those expressing no preference received the 1CU accommodating IOL. Efficacy measures included distance and near uncorrected visual acuity (UCVA), dynamic retinoscopy, and patient-reported spectacle independence. Results: Seventeen patients (34 eyes) had bilateral implantation of the Array multifocal IOL, and 5 patients (9 eyes) had implantation of the 1CU accommodating IOL. Six to 18 months after surgery, 82.4% of eyes in the multifocal IOL group and 77.8% in the accommodating IOL group achieved a distance UCVA of 20/20 (Snellen) or better; the difference between groups was not significant. However, a significantly greater proportion in the multifocal IOL group than in the accommodating IOL group (76.5% versus 44.4%) achieved a near UCVA of N5 (Snellen 20/40) or better (P = .0068). Sixteen patients (94.1%) with Array IOLs and 2 patients (50.0%) with 1CU IOLs reported spectacle independence. Dynamic retinoscopy showed that the mean accommodative effect in the 1CU group was 0.44 diopter. Conclusions: In this single-surgeon single-site study, a greater proportion of Array multifocal IOL recipients than 1CU IOL recipients achieved functional near visual acuity. Only 1 patient with an Array IOL required corrective spectacles at the last visit. (C) 2004 ASCRS and ESCRS.
引用
收藏
页码:2088 / 2091
页数:4
相关论文
共 11 条
[1]   Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomes - Multicenter clinical trial in Germany and Austria [J].
Javitt, J ;
Brauweiler, HP ;
Jacobi, KW ;
Klemen, U ;
Kohnen, S ;
Quentin, CD ;
Teping, C ;
Pham, T ;
Knorz, MC ;
Poetzsch, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09) :1356-1366
[2]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[3]   Outcomes of cataract extraction with multifocal intraocular lens implantation - Functional status and quality of life [J].
Javitt, JC ;
Wang, F ;
Trentacost, DJ ;
Rowe, M ;
Tarantino, N .
OPHTHALMOLOGY, 1997, 104 (04) :589-599
[4]   Two years experience with the new accommodative 1 CU intraocular lens [J].
Küchle, M ;
Nguyen, NX ;
Langenbucher, A ;
Gusek-Schneider, GC ;
Seitz, B .
OPHTHALMOLOGE, 2002, 99 (11) :820-824
[5]  
Küchle M, 2002, J REFRACT SURG, V18, P208
[6]   Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens [J].
Langenbucher, A ;
Huber, S ;
Nguyen, NX ;
Seitz, B ;
Gusek-Schneider, GC ;
Küchle, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :677-685
[7]   Cardinal points and image-object magnification with an accommodative lens implant (1 CU) [J].
Langenbucher, A ;
Huber, S ;
Nguyen, NX ;
Seitz, B ;
Küchle, M .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (01) :61-70
[8]  
LEYLAND M, 2004, MULTIFOCAL VERSUS MO
[9]   A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens [J].
Steinert, RF ;
Aker, BL ;
Trentacost, DJ ;
Smith, PJ ;
Tarantino, N .
OPHTHALMOLOGY, 1999, 106 (07) :1243-1255
[10]  
STEINERT RF, 1992, OPHTHALMOLOGY, V99, P853