Study of a method based on TLD detectors for in-phantom dosimetry in BNCT

被引:18
作者
Gambarini, G
Klamert, V
Agosteo, S
Birattari, C
Gay, S
Rosi, G
Scolari, L
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Natl Inst Nucl Phys, I-20133 Milan, Italy
[3] Politecn Milan, Dept Nucl Engn, CESNEF, I-20133 Milan, Italy
[4] ENEA, FIS ION, I-00060 Rome, Italy
关键词
D O I
10.1093/rpd/nch109
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF2:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different Li-6 percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity.
引用
收藏
页码:631 / 636
页数:6
相关论文
共 13 条
  • [1] [Anonymous], 1996, 40371 ISO
  • [2] COMPARISON OF THERMAL-NEUTRON AND GAMMA-RAY SENSITIVITIES OF COMMON TLD MATERIALS
    AYYANGAR, K
    LAKSHMANAN, AR
    CHANDRA, B
    RAMADAS, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (05) : 665 - 676
  • [3] BENSHACHAR B, 1985, NUCL SOC ISRAEL T, V12, P113
  • [4] THERMOLUMINESCENT RESPONSE OF THULIUM ACTIVATED CALCIUM FLUORIDES TO COPPER K-ALPHA X-RADIATION
    CHIOU, BS
    LIU, JI
    HSU, PC
    WENG, PS
    [J]. RADIATION PROTECTION DOSIMETRY, 1988, 22 (02) : 115 - 117
  • [5] DIELHOF JB, 1988, RADIAT PROT DOSIM, V23, P405
  • [6] Fricke gel dosimetry in boron neutron capture therapy
    Gambarini, G
    Birattari, C
    Colombi, C
    Pirola, L
    Rosi, G
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 419 - 422
  • [7] TL dosimetry in high fluxes of thermal neutrons using variously doped LiF and KMgF3
    Gambarini, G
    Martini, M
    Scacco, A
    Raffaglio, C
    Sichirollo, AE
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 175 - 180
  • [8] Imaging and profiling of absorbed dose in neutron capture therapy
    Gambarini, G
    Agosteo, S
    Danesi, U
    Garbellini, F
    Lietti, B
    Mauri, M
    Rosi, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 780 - 784
  • [9] GIBSON JAB, 1986, RADIAT PROT DOSIM, V15, P253
  • [10] FAST AND THERMAL-NEUTRON RESPONSE OF BEO AND LI2B4O7-MN IN COMPARISON WITH LIF AND CAF2
    HENAISH, BA
    SAYED, AM
    MORSY, SM
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 395 - 399