Comparison of transprosthetic mean pressure gradients between Medtronic Hall and ATS valves in the aortic position

被引:9
作者
Sung, M [1 ]
Park, PW [1 ]
Park, KH [1 ]
Jun, TG [1 ]
Lee, YT [1 ]
Yang, JH [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Sch Med, Seoul 135710, South Korea
关键词
aortic valve replacement; transprosthetic pressure gradient; Medtronic Hall valve; ATS valve;
D O I
10.1016/j.ijcard.2003.10.066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim of the study: Several studies have shown the inferior performance of small prostheses in the narrow aortic root. However, modem low-profile mechanical prostheses have improved hemodynamic performance characteristics. By measuring the transprosthetic pressure gradient in vivo, we were able to characterize the hemodynamic features of two prostheses: the ATS Medical (ATS) and the Medtronic Hall (MH) valves. Methods: From October 1994 to April 2002, 113 patients received an aortic valve replacement (AVR) with either an ATS or a MH valve. The transprosthetic pressure gradients, calculated from a simplified Bernoulli equation during immediate postoperative Doppler echocardiographic examination, were compared for differently sized prostheses with respect to body surface area (BSA). Results: The mean pressure gradients and the mean BSAs were: 27.8 +/- 14.8 mm Hg and 1.50 +/- 0.10 m(2) in ATS 19 mm (n = 7), 20.4 +/- 8.5 mm Hg and 1.54 +/- 0.11 m(2) in ATS 21 mm (n = 22), 13.0 +/- 5.7 mm Hg, 1.70 +/- 0.13 m(2) in ATS 23 mm (n = 22), 10.9 +/- 3.5 mm Hg and 1.81 +/- 0.16 m(2) in ATS 25 mm (n = 19), 9.3 +/- 0.6 mm Hg and 1.72 +/- 0.17 m(2) in ATS 27 mm (n = 4), 13.5 +/- 6.5 mm Hg and 1.54 0.13 m(2) in MH 20 m(2), (n = 9), 10.9 +/- 4.7 mm Hg and 1.64 +/- 0.15 m(2) in MH 22 mm (n = 22), 9.3 +/- 3.1 mm Hg and 1.72 +/- 0.12 m(2) in MH 24 mm (n 7). Conclusions: With the exception of the ATS 19-mm valve, the variously sized prostheses have acceptable transprosthetic pressure gradient measurements. In addition, even-sized MH valves (20 and 22 mm) with a thinner sewing cuff showed better hemodynamic performances than similarly sized ATS valves. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 33 条
[1]   Impact of small prosthetic valve size on operative mortality in elderly patients after aortic valve replacement for aortic stenosis: Does gender matter? [J].
Adams, DH ;
Chen, RH ;
Kadner, A ;
Aranki, SF ;
Allred, EN ;
Cohn, LH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (05) :815-822
[2]  
Aris A, 1996, J HEART VALVE DIS, V5, P459
[3]   10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS [J].
AROM, KV ;
NICOLOFF, DM ;
KERSTEN, TE ;
NORTHRUP, WF ;
LINDSAY, WG ;
EMERY, RW .
ANNALS OF THORACIC SURGERY, 1989, 47 (06) :831-837
[4]  
Autschbach R, 2000, CIRCULATION, V102, P1
[5]   DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[6]   Postoperative exercise tolerance after aortic valve replacement by small-size prosthesis - Functional consequence of small-size aortic prosthesis [J].
Becassis, P ;
Hayot, M ;
Frapier, JM ;
Leclercq, F ;
Beck, L ;
Brunet, J ;
Arnaud, E ;
Prefaut, C ;
Chaptal, PA ;
Davy, JM ;
Messner-Pellenc, P ;
Grolleau, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :871-877
[7]  
Brazao AJ, 1999, J HEART VALVE DIS, V8, P680
[8]   Twenty years' experience with the Medtronic Hall valve [J].
Butchart, EG ;
Li, HH ;
Payne, N ;
Buchan, K ;
Grunkemeier, GL .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (06) :1090-1100
[9]  
David T E, 1992, J Heart Valve Dis, V1, P244
[10]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618