Task group 284 report: magnetic resonance imaging simulation in radiotherapy: considerations for clinical implementation, optimization, and quality assurance

被引:87
作者
Glide-Hurst, Carri K. [1 ]
Paulson, Eric S. [2 ]
McGee, Kiaran [3 ]
Tyagi, Neelam [4 ]
Hu, Yanle [5 ]
Balter, James [6 ]
Bayouth, John [1 ]
机构
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
[2] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
[3] Mayo Clin, Dept Diagnost Radiol, Rochester, MN 55905 USA
[4] Mem Sloan Kettering Canc Ctr, Med Phys Dept, New York, NY 10065 USA
[5] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ 85054 USA
[6] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
magnetic resonance simulation; MR-SIM; quality assurance; radiotherapy; CERVIX CANCER BRACHYTHERAPY; TARGET VOLUME DELINEATION; RADIATION-THERAPY; GEOMETRIC DISTORTION; CT-MRI; INTENSITY NONUNIFORMITY; PROSTATE RADIOTHERAPY; T MRI; FIELD; SUSCEPTIBILITY;
D O I
10.1002/mp.14695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to be addressed for safe and effective MR-SIM implementation. The major objectives of this report are to provide recommendations for commercially available MR simulators, including initial equipment selection, siting, acceptance testing, quality assurance, optimization of dedicated radiation therapy specific MR-SIM workflows, patient-specific considerations, safety, and staffing. Major contributions include guidance on motion and distortion management as well as MRI coil configurations to accommodate patients immobilized in the treatment position. Examples of optimized protocols and checklists for QA programs are provided. While the recommendations provided here are minimum requirements, emerging areas and unmet needs are also highlighted for future development.
引用
收藏
页码:E636 / E670
页数:35
相关论文
共 138 条
[1]  
AAPM Professional Policy 18-B, STAT DESCR INV MED P STAT DESCR INV MED P
[2]   Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer [J].
Adjeiwaah, Mary ;
Bylund, Mikael ;
Lundman, Josef A. ;
Karlsson, Camilla Thellenberg ;
Jonsson, Joakim H. ;
Nyholm, Tufve .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (02) :317-324
[3]   Phase insensitive preparation of single-shot RARE: Application to diffusion imaging in humans [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :527-533
[4]  
American College of Radiology, 2018, PHANT TEST GUID US L
[5]  
[Anonymous], 2020, AM COLL RADIOLOGY MA, P20201
[6]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[7]   A two-step scheme for distortion rectification of magnetic resonance images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2009, 36 (09) :3917-3926
[8]   Boosting imaging defined dominant prostatic tumors: A systematic review [J].
Bauman, Glenn ;
Haider, Masoom ;
Van der Heide, Uulke A. ;
Menard, Cynthia .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) :274-281
[9]   Intensity non-uniformity correction in MRI: Existing methods and their validation [J].
Belaroussi, B ;
Milles, J ;
Carme, S ;
Zhu, YM ;
Benoit-Cattin, H .
MEDICAL IMAGE ANALYSIS, 2006, 10 (02) :234-246
[10]   Real-time RF pulse adjustment for B0 drift correction [J].
Benner, Thomas ;
van der Kouwe, Andre J. W. ;
Kirsch, John E. ;
Sorensen, A. Gregory .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) :204-209