A new plastic optical fiber sensor for oxygen based on fluorescence enhancement

被引:13
作者
Vishnoi, G [1 ]
Morisawa, M [1 ]
Muto, S [1 ]
机构
[1] Yamanashi Univ, Fac Engn, Dept Elect Engn & Comp Sci, Kofu, Yamanashi 400, Japan
关键词
oxygen sensor; fluorescence enhancement; plastic optical fiber ARTON fiber; PMP (poly-4-methyl-1-pentene); TPP (tetraphenylporphine);
D O I
10.1007/s10043-998-0013-0
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new method far the detection of low oxygen concentration is proposed here. The system is based on the principle of enhancement of fluorescence yield of tetraphenylporphine (TPP) dye at lambda=656 nm when excited by He-Cd laser at lambda=441 nm in the presence of oxygen. The sensor head was fabricated by cladding the ARTON fiber core with the poly-4-methyl-1-pentene polymer matrix doped with TPP. The experimental results obtained indicate a good enhancement in the fluorescence when the sensor head is exposed to oxygen. The response was found to be linear and stable in the range of (100 ppm-1%) with the resolution of 0.01%. The sensor response was characterized by studying its response for change in temperature and is discussed below.
引用
收藏
页码:13 / 15
页数:3
相关论文
共 2 条
[1]  
DAKIN J, 1997, OPTICAL FIBER SENSOR, V4, P84
[2]   Studies on the improvement of sensitivity and stability of fiber optic oxygen sensing based on cladding fluorescence [J].
Vishnoi, G ;
Morisawa, M ;
Mizukami, T ;
Uchiyama, K ;
Muto, S .
CHEMICAL, BIOCHEMICAL, AND ENVIRONMENTAL FIBER SENSORS IX, 1997, 3105 :114-121