Thermal behavior of an electrical motor through a reduced model

被引:33
作者
Bertin, Y [1 ]
Videcoq, E [1 ]
Thieblin, S [1 ]
Petit, D [1 ]
机构
[1] ENSMA, Lab Etud Therm, F-86960 Futuroscope, France
关键词
electrical motor; thermal modeling; transient response; model reduction;
D O I
10.1109/60.866989
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this study is to obtain quickly thermal information on some sensitive components of an electrical motor in a short lapse of time. The thermal behavior of this complex system is modeled and validated. The corresponding detailed model leads to the resolution of a linear system of differential equations of high order, but is not easy to handle for control purposes, due to long CPU time, In order to compute faster, two model reduction techniques are used: the Eitelberg method and the reduction by modal identification. The reduced models effectively give good temperature accuracy on the critical points of the motor with very fast computation time.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 12 条
[1]  
Becker K., 1962, T ASME J HEAT TRANSF, V84, P97
[2]   COMMENTS ON MODEL-REDUCTION BY MINIMIZING THE EQUATION ERROR [J].
EITELBERG, E .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1982, 27 (04) :1000-1002
[3]   A MODEL-REDUCTION TECHNIQUE SUITABLE FOR OPTIMAL CONTROLLER-DESIGN IN HIGH-ORDER POWER-SYSTEMS [J].
EITELBERG, E ;
BALDA, JC ;
HARLEY, RG .
ELECTRIC POWER SYSTEMS RESEARCH, 1987, 12 (01) :51-62
[4]  
*GEN HEAT CO, HEAT TRANSF FLUID FL
[5]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[6]  
Hay N., 1993, ASME WINT ANN M NEW
[7]  
Oslejsek O., 1972, Elektrotechnicky Obzor, V61, P548
[8]  
PETIT D, 1997, INT J MODELING SIMUL, V17
[9]  
TAKAHASHI K, 1997, EXPT HEAT TRANSFER F, P349
[10]  
TAYLOR GI, 1923, PHILOS T ROY SOC LON, VA, P223