Transapical transcatheter aortic valve implantation: Follow-up to 3 years

被引:93
作者
Ye, Jian [1 ]
Cheung, Anson [1 ]
Lichtenstein, Samuel V. [1 ]
Nietlispach, Fabian [2 ]
Albugami, Saad [2 ]
Masson, Jean-Bernard [2 ]
Thompson, Christopher R. [2 ]
Munt, Brad [2 ]
Moss, Robert [2 ]
Carere, Ronald G. [2 ]
Jamieson, W. R. Eric [1 ]
Webb, John G. [2 ]
机构
[1] Univ British Columbia, Div Cardiac Surg, St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[2] Univ British Columbia, Div Cardiol, St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
关键词
TRANSLUMINAL IMPLANTATION; HEART-VALVES; REPLACEMENT; PROSTHESIS; STENOSIS;
D O I
10.1016/j.jtcvs.2009.10.056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We performed the first human case of successful transapical transcatheter aortic valve implantation on a beating heart in October 2005, and therefore we have the longest follow-up on transapical aortic valve implantation in humans. We now report clinical and echocardiographic outcomes of transapical aortic valve implantation in 71 patients. Methods: Between October 2005 and February 2009, 71 patients (44 female) underwent transcatheter transapical aortic valve implantation with either 23- or 26-mm Edwards Lifesciences transcatheter bioprostheses. All patients with symptomatic aortic stenosis were declined for conventional aortic valve replacement owing to unacceptable operative risks and were not candidates for transfemoral aortic valve implantation because of poor arterial access. Clinical and echocardiographic follow-ups were performed before discharge, at 1 and 6 months, and then yearly. The mean follow-up was 12.9 +/- 11.5 months with a total of 917.3 months of follow-up. Results: Mean age was 80.0 +/- 8.1 years and predicted operative mortality was 34.5% +/- 20.4% by logistic EuroSCORE and 12.1% +/- 7.7% by The Society of Thoracic Surgeons Risk Calculator. Valves were successfully implanted in all patients. Twelve patients died within 30 days (30-day mortality: 16.9% in all patients, 33% in the first 15 patients, and 12.5% in the remainder), and 10 patients died subsequently. Overall survival at 24 and 36 months was 66.3% +/- 6.4% and 58.0% +/- 9.5%, respectively. Among 59 patients who survived at least 30 days, 24- and 36-month survivals were 79.8% +/- 6.4% and 69.8% +/- 10.9%, respectively. Late valve-related complications were rare. New York Heart Association functional class improved significantly from preoperative 3.3 +/- 0.8 to 1.8 +/- 0.8 at 24 months. The aortic valve area and mean gradient remained stable at 24 months (1.6 +/- 0.3 cm(2) and 10.3 +/- 5.9 mm Hg, respectively). Conclusion: Our outcome suggests that transapical transcatheter aortic valve implantation provides sustained clinical and hemodynamic benefits for up to 36 months in selected high-risk patients with symptomatic severe aortic stenosis. (J Thorac Cardiovasc Surg 2010; 139: 1107-13)
引用
收藏
页码:1107 / U27
页数:8
相关论文
共 23 条
[1]   TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[2]   Steps toward percutaneous aortic valve replacement [J].
Boudjemline, Y ;
Bonhoeffer, P .
CIRCULATION, 2002, 105 (06) :775-778
[3]   Percutaneous aortic valve implantation: A case report [J].
Chandavimol, Mann ;
McClure, Samuel J. ;
Carere, Ron G. ;
Thompson, Christopher R. ;
Ricci, Donald R. ;
Mackay, Martha H. ;
Webb, John G. .
CANADIAN JOURNAL OF CARDIOLOGY, 2006, 22 (13) :1159-1161
[4]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[5]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[6]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[7]  
Cribier A, 2001, CIRCULATION, V104, P552
[8]  
Glock Y, 1996, Cardiovasc Surg, V4, P241, DOI 10.1016/0967-2109(96)82324-6
[9]   First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve [J].
Grube, E ;
Laborde, JC ;
Zickmann, B ;
Gerckens, U ;
Felderhoff, T ;
Sauren, B ;
Bootsveld, A ;
Buellesfeld, L ;
Iversen, S .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) :465-469
[10]   DOPPLER COLOR FLOW MAPPING IN THE EVALUATION OF PROSTHETIC MITRAL AND AORTIC-VALVE FUNCTION [J].
KAPUR, KK ;
FAN, P ;
NANDA, NC ;
YOGANATHAN, AP ;
GOYAL, RG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) :1561-1571