Investigation of through beam connection to concrete filled circular steel tube (CFCST) column

被引:159
作者
Khanouki, M. M. Arabnejad [1 ]
Sulong, N. H. Ramli [1 ]
Shariati, Mandi [1 ]
Tahir, M. M. [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Civil Engn, Kuala Lumpur 50603, Malaysia
[2] UTM, Fac Civil Engn, UTM Construct Res Ctr, Inst Smart Infrastruct & Innovat Construct, Johor Baharu 81310, Johor, Malaysia
关键词
Concrete filled tube columns; Through beam connection; Finite element analysis; Steel and concrete damage; Weld fractured; Buckling analysis; FINITE-ELEMENT-ANALYSIS; STUB COLUMNS; CFT COLUMN; EXPERIMENTAL BEHAVIOR; SEISMIC BEHAVIOR; COMPOSITE BEAMS; PERFORMANCE; STIFFENERS; CFSSTCS; MOMENT;
D O I
10.1016/j.jcsr.2016.01.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nonlinear finite element models of through beam connection to concrete filled circular steel tube (CFCST) column with three types of connection failures (column, beam and joint shear failures) under monotonic loading were proposed by ABAQUS programme. The connection detail composed of a steel I-beam which is completely passed through the circular steel tube column and welded to it by fillet or full penetration weld and the tube is then filled with concrete. The connection parameters investigated included different ratios of column-to-beam flexural strength, fillet or full penetration weld to connect the beam to the tube, using rebar inside of the column and effect of beam web and concrete core inside the joint. Buckling analysis, concrete damage, weld fractured and tube tearing were defined in the model. Good agreement was achieved between the model and existing test results in terms of the beam tip force-storey drift relationship, joint distortion and joint shear strain. As a result, the models could correctly predict the linear, nonlinear and post-failure behaviours of the connection. In addition, other parameters of the connection were investigated for the specimens. Finally, the effect of column axial load level for the connection behaviour in the three types of failures was investigated as a parametric study. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:144 / 162
页数:19
相关论文
共 34 条
[1]  
*ACI COMM, 1995, BUILD COD REQ STRUCT
[2]   Analytical behavior of connections to concrete-filled steel tubes [J].
Alostaz, YM ;
Schneider, SP .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 40 (02) :95-127
[3]  
[Anonymous], 2010, 34110 ANSIAISC
[4]  
[Anonymous], 1997, 8110 BSIBS 1
[5]  
[Anonymous], 2004, EN199211
[6]  
[Anonymous], 1992, ENV199211 CEN
[7]  
[Anonymous], 2006, STAND US MAN VERS 6
[8]  
ASCE, 1994, J STRUCT ENG-ASCE, V120, P30
[9]   Moment connections to circular concrete-filled steel tube columns [J].
Azizinamini, A ;
Schneider, SP .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (02) :213-222
[10]   DESIGN OF THROUGH BEAM CONNECTION DETAIL FOR CIRCULAR COMPOSITE COLUMNS [J].
AZIZINAMINI, A ;
SHEKAR, Y ;
SAADEGHVAZIRI, MA .