Time-resolved fluorescence imaging in islet cell autoantibody quantitation

被引:24
|
作者
Rulli, M
Kuusisto, A
Salo, J
Kojola, H
Simell, O
机构
[1] Univ Turku, Dept Pediat, FIN-20520 Turku 52, Finland
[2] Univ Turku, MediCity Res Lab, FIN-20520 Turku, Finland
[3] Wallac Oy, FIN-20101 Turku, Finland
关键词
insulin-dependent diabetes; islet cell antibodies; lanthanides; europium chelate; time-resolved fluorescence imaging;
D O I
10.1016/S0022-1759(97)00145-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The prodromal period of insulin-dependent diabetes mellitus (IDDM) is characterized by circulating islet cell autoantibodies (ICA) and other beta cell specific autoantibodies. Despite biochemical characterization of the major beta cell autoantigens insulin, glutamic acid decarboxylase and protein tyrosine phosphatase and development of the respective antibody assays, ICA has remained the standard in IDDM prediction. Conventional ICA quantitation using classic fluorochromes is prone to errors since fluorescence intensity is estimated subjectively using the human eye, which is also unable to differentiate specific signals from non-specific signals and autofluorescence. Using Eu3+-chelate labelled anti-human polyclonal IgG (decay time 1000 mu s) as the secondary antibody in time-resolved fluorescence imaging (TRFI), the chelate and autofluorescence signals (typical decay time < 100 ns) are fully separated. The image is recorded using an optically gated cooled digital CCD camera. The specificity of the ICA signal is further improved by interactive analysis of the image. Signal detection is objective, the signal-to-background ratio improves, and ICA quantitation is possible using undiluted serum. Of 57 consecutive new-onset IDDM patients, 55 (96.5%) were ICA positive in the new assay while 51 (89.5%) were positive in the conventional assay suggesting that the sensitivity of TRFI exceeds that of the IAA, GAD(65) and IA-2 autoantibody assays combined. For later comparisons, the stained slides may be stored in the light for years without any decrease in specific fluorescence. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:169 / 179
页数:11
相关论文
共 50 条
  • [11] Time-resolved fluorescence imaging of solvent interactions in microfluidic devices
    Benninger, RKP
    Hofmann, O
    McGinty, J
    Requejo-Isidro, J
    Munro, I
    Neil, MAA
    deMello, AJ
    French, PMW
    OPTICS EXPRESS, 2005, 13 (16) : 6275 - 6285
  • [12] Time-resolved fluorescence spectroscopy
    Millar, DP
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 1996, 6 (05) : 637 - 642
  • [13] TIME-RESOLVED FLUORESCENCE OF PROTEINS
    BEECHEM, JM
    BRAND, L
    ANNUAL REVIEW OF BIOCHEMISTRY, 1985, 54 : 43 - 71
  • [14] TIME-RESOLVED FLUORESCENCE SPECTROSCOPY
    HOLZWARTH, AR
    BIOCHEMICAL SPECTROSCOPY, 1995, 246 : 334 - 362
  • [15] Time-resolved fluorescence microscopy
    Suhling, K
    French, PMW
    Phillips, D
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2005, 4 (01) : 13 - 22
  • [16] TIME-RESOLVED FLUORESCENCE OF POLYANILINE
    THORNE, JRG
    MASTERS, JG
    WILLIAMS, SA
    MACDIARMID, AG
    HOCHSTRASSER, RM
    SYNTHETIC METALS, 1992, 49 (1-3) : 159 - 165
  • [17] Time-resolved fluorescence microscopy
    Suhling, Klaus
    Tregidgo, Carolyn
    Sergent, Nicolas
    Levitt, James A.
    Pavlides, Alex
    Green, Mark
    Hungerford, Graham
    Rei, Ana
    Ferreira, M. Isabel C.
    ADVANCED PHOTON COUNTING TECHNIQUES II, 2007, 6771
  • [18] Fluorescence time-resolved macroimaging
    Shcheslavskiy, Vladislav, I
    Shirmanova, Marina, V
    Dudenkova, Varvara V.
    Lukyanov, Konstantin A.
    Gavrina, Alena, I
    Shumilova, Anastasia, V
    Zagaynova, Elena
    Becker, Wolfgang
    OPTICS LETTERS, 2018, 43 (13) : 3152 - 3155
  • [19] Time-resolved fluorescence microscopy
    Klaus Suhling
    Paul M. W. French
    David Phillips
    Photochemical & Photobiological Sciences, 2005, 4 : 13 - 22
  • [20] A TIME-RESOLVED FLUORESCENCE MICROSCOPE
    FRENCH, T
    SO, P
    BERLAND, K
    GRATTON, E
    BIOPHYSICAL JOURNAL, 1993, 64 (02) : A110 - A110