Time-resolved fluorescence imaging in islet cell autoantibody quantitation

被引:24
作者
Rulli, M
Kuusisto, A
Salo, J
Kojola, H
Simell, O
机构
[1] Univ Turku, Dept Pediat, FIN-20520 Turku 52, Finland
[2] Univ Turku, MediCity Res Lab, FIN-20520 Turku, Finland
[3] Wallac Oy, FIN-20101 Turku, Finland
关键词
insulin-dependent diabetes; islet cell antibodies; lanthanides; europium chelate; time-resolved fluorescence imaging;
D O I
10.1016/S0022-1759(97)00145-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The prodromal period of insulin-dependent diabetes mellitus (IDDM) is characterized by circulating islet cell autoantibodies (ICA) and other beta cell specific autoantibodies. Despite biochemical characterization of the major beta cell autoantigens insulin, glutamic acid decarboxylase and protein tyrosine phosphatase and development of the respective antibody assays, ICA has remained the standard in IDDM prediction. Conventional ICA quantitation using classic fluorochromes is prone to errors since fluorescence intensity is estimated subjectively using the human eye, which is also unable to differentiate specific signals from non-specific signals and autofluorescence. Using Eu3+-chelate labelled anti-human polyclonal IgG (decay time 1000 mu s) as the secondary antibody in time-resolved fluorescence imaging (TRFI), the chelate and autofluorescence signals (typical decay time < 100 ns) are fully separated. The image is recorded using an optically gated cooled digital CCD camera. The specificity of the ICA signal is further improved by interactive analysis of the image. Signal detection is objective, the signal-to-background ratio improves, and ICA quantitation is possible using undiluted serum. Of 57 consecutive new-onset IDDM patients, 55 (96.5%) were ICA positive in the new assay while 51 (89.5%) were positive in the conventional assay suggesting that the sensitivity of TRFI exceeds that of the IAA, GAD(65) and IA-2 autoantibody assays combined. For later comparisons, the stained slides may be stored in the light for years without any decrease in specific fluorescence. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:169 / 179
页数:11
相关论文
共 50 条
  • [11] 340 nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection
    Rodenko, Olga
    Fodgaard, Henrik
    Tidemand-Lichtenberg, Peter
    Pedersen, Christian
    OPTICAL DIAGNOSTICS AND SENSING XVII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2017, 10072
  • [12] SENSITIVE TIME-RESOLVED FLUOROIMMUNOASSAY OF SALMON-CALCITONIN
    RONG, HQ
    TORRING, O
    SAAF, M
    SJOSTEDT, U
    SJOBERG, HE
    BUCHT, E
    CLINICAL CHEMISTRY, 1994, 40 (09) : 1774 - 1777
  • [13] Islet cell autoantibody levels after the diagnosis of young adult diabetic patients
    Jensen, R.
    Gilliam, L.
    Torn, C.
    Landin-Olsson, M.
    Palmer, J.
    Akesson, K.
    Kockum, I.
    Lernmark, B.
    Karlsson, A. F.
    Lynch, K. F.
    Breslow, N.
    Lernmark, A.
    Sundkvist, G.
    DIABETIC MEDICINE, 2007, 24 (11) : 1221 - 1228
  • [14] Time-resolved laser-induced fluorescence spectroscopy of Nd3+ in molten LiCl-KCl eutectic
    Jung, E. C.
    Bae, S. -E.
    Park, Y. J.
    Song, K.
    CHEMICAL PHYSICS LETTERS, 2011, 516 (4-6) : 177 - 181
  • [15] TIME-RESOLVED FLOW-CYTOMETRY FOR THE MEASUREMENT OF LANTHANIDE CHELATE FLUORESCENCE .2. INSTRUMENT DESIGN AND EXPERIMENTAL RESULTS
    CONDRAU, MA
    SCHWENDENER, RA
    ZIMMERMANN, M
    MUSER, MH
    GRAF, U
    NIEDERER, P
    ANLIKER, M
    CYTOMETRY, 1994, 16 (03): : 195 - 205
  • [16] Luminescent Terbium Protein Labels for Time-Resolved Microscopy and Screening
    Rajapakse, Harsha E.
    Reddy, D. Rajasekhar
    Mohandessi, Shabnam
    Butlin, Nathaniel G.
    Miller, Lawrence W.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (27) : 4990 - 4992
  • [17] Influence of the solvent on the complexation of Cm(III) and Eu(III) with nPr-BTP studied by time-resolved laser fluorescence spectroscopy
    Bremer, Antje
    Muellich, Udo
    Geist, Andreas
    Panak, Petra J.
    NEW JOURNAL OF CHEMISTRY, 2015, 39 (02) : 1330 - 1338
  • [18] Isolation and characterisation of a human monoclonal autoantibody to the islet cell autoantigen IA-2
    Ananieva-Jordanova, R
    Evans, M
    Nakamatsu, T
    Premawardhana, LDKE
    Sanders, J
    Powell, M
    Chen, S
    McGrath, V
    Belton, C
    Arnold, C
    Baker, S
    Betterle, C
    Zanchetta, R
    Smith, BR
    Furmaniak, J
    JOURNAL OF AUTOIMMUNITY, 2005, 24 (04) : 337 - 345
  • [19] Novel flashlamp based time-resolved fluorescence microscope reduces autofluorescence for 30-fold contrast enhancement in environmental samples
    Connally, R
    Veal, D
    Piper, J
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING X, 2003, 4964 : 14 - 23
  • [20] Preparation of specific antiserum of secretin and its use in time-resolved fluoroimmunoassay
    Ito, K
    Kodama, R
    Maeda, M
    Tsuji, A
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1995, 115 (12): : 985 - 991