Sandwich-structured displays encapsulating polystyrene microspheres coated with Fe3O4 nanoparticles for label-free biosensing for electrorheological operation

被引:20
作者
Guo, Jian-Wei [1 ,2 ]
Lin, Feng-Ping [2 ,3 ]
Chang, Chi-Jung [4 ]
Lu, Chien-Hsing [5 ,6 ]
Chen, Jem-Kun [2 ]
机构
[1] Guangdong Univ Technol, Sch Chem Engn & Light Ind, Guangzhou, Guangdong, Peoples R China
[2] Natl Taiwan Univ Sci & Technol, Taiwan Bldg Technol Ctr, Dept Mat Sci & Engn, 43,Sect 4,Keelung Rd, Taipei 10607, Taiwan
[3] Natl Def Med Ctr, Inst Prevent Med, 161,Sect 6,Minquan E Rd, New Taipei, Taiwan
[4] Feng Chia Univ, Dept Chem Engn, 100 Wenhwa Rd, Taichung 40724, Taiwan
[5] Taichung Vet Gen Hosp, Dept Obstet & Gynecol, Taichung, Taiwan
[6] Natl Yang Ming Univ, Sch Med, Dept Obstet & Gynecol, Taipei, Taiwan
关键词
Core/shell; Fe3O4; nanoparticle; Polystyrene microsphere; Electrorheology; SHELL; FLUIDS; ADSORPTION;
D O I
10.1016/j.snb.2019.127185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Core/shell structures consisting of polystyrene microspheres (PM, similar to 2.2 mu m) and Fe3O4 nanoparticles (FeNPs, similar to 12.7 nm) were synthesized using a layer-by-layer process to vary the dielectric property. PM@FeNP solutions were encapsulated into home-made sandwich-structured displays (SSDs) to observe their transmittance change under an alternating electric field (AEF). The dispersed PM@FeNP blocked the light traveling through the SSD in the absence of AEF, resulting in an opaque state. In the presence of an AEF, the SSD could display the highest transmittance at the so-called characteristic frequency of the encapsulated microspheres, because of particle chaining. Furthermore, protein G and an antibody were coated onto the PM@FeNP, denoted as PM@FeNP@GIg, for use as a biosensor medium. The characteristic frequency of PM@FeNP@GIg shifted from 300 kHz to 750 kHz after antigen coupling, which could be visualized without any labeling because of the significant change in transmittance. The limit of detection (LOD), similar to 40 ng/mu L, could be identified within 30 s by the highest transmittance of SSD under AEF at 750 kHz. The transmittance was not affected by BSA or streptavidin, indicating high sensitivity and selectivity. This technique significantly simplifies common immunoassays, which may possess great potential for practical applications in label-free biosensors and visualizing antigen.
引用
收藏
页数:13
相关论文
共 42 条
[1]   An ultrasensitive flexible pressure sensor for multimodal wearable electronic skins based on large-scale polystyrene ball@reduced graphene-oxide core-shell nanoparticles [J].
Ai, Yuanfei ;
Hsu, Ting Heng ;
Wu, Ding Chou ;
Lee, Ling ;
Chen, Jyun-Hong ;
Chen, Yu-Ze ;
Wu, Shu-Chi ;
Wu, Cuo ;
Wang, Zhiming M. ;
Chueh, Yu-Lun .
JOURNAL OF MATERIALS CHEMISTRY C, 2018, 6 (20) :5514-5520
[2]   Design and dynamic modeling of electrorheological fluid-based variable-stiffness fin for robotic fish [J].
Behbahani, Sanaz Bazaz ;
Tan, Xiaobo .
SMART MATERIALS AND STRUCTURES, 2017, 26 (08)
[3]   Solidification of oil liquids by encapsulation within porous hollow silica microspheres of narrow size distribution for pharmaceutical and cosmetic applications [J].
Belostozky, A. ;
Bretler, S. ;
Kolitz-Domb, M. ;
Grinberg, I. ;
Margel, S. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 97 :760-767
[4]   Patterned 3D assembly of Au nanoparticle on silicon substrate by colloid lithography [J].
Chen, Jem-Kun ;
Qui, Jia-Qi .
JOURNAL OF NANOPARTICLE RESEARCH, 2012, 14 (06)
[5]   Using colloid lithography to fabricate silicon nanopillar arrays on silicon substrates [J].
Chen, Jem-Kun ;
Qui, Jia-Qi ;
Fan, Shih-Kang ;
Kuo, Shiao-Wei ;
Ko, Fu-Hsiang ;
Chu, Chih-Wei ;
Chang, Feng-Chih .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 367 :40-48
[6]   Nanowires of 3-D cross-linked gold nanoparticle assemblies behave as thermosensors on silicon substrates [J].
Chen, Jem-Kun ;
Qui, Jia-Qi .
COLLOID AND POLYMER SCIENCE, 2011, 289 (17-18) :1829-1837
[7]   Liquid Lenses and Driving Mechanisms: A Review [J].
Chiu, Cheng-Pu ;
Chiang, Tsai-Jung ;
Chen, Jem-Kun ;
Chang, Feng-Chih ;
Ko, Fu-Hsiang ;
Chu, Chih-Wei ;
Kuo, Shiao-Wei ;
Fan, Shih-Kang .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2012, 26 (12-17) :1773-1788
[8]   Cellulose-Based Smart Fluids under Applied Electric Fields [J].
Choi, Kisuk ;
Gao, Chun Yan ;
Nam, Jae Do ;
Choi, Hyoung Jin .
MATERIALS, 2017, 10 (09)
[9]   Bingham Characteristics of Polymer-Based Electrorheological Fluids with Different Electrode Gaps and Materials [J].
Choi, S. B. ;
Han, Y. M. ;
Sohn, J. W. ;
Choi, H. J. .
JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 114 (06) :3636-3644
[10]   Recent development of electro-responsive smart electrorheological fluids [J].
Dong, Yu Zhen ;
Seo, Yongsok ;
Choi, Hyoung Jin .
SOFT MATTER, 2019, 15 (17) :3473-3486