The interaction between fentanyl and propofol during emergence from anesthesia:: Monitoring with the EEG-Bispectral Index™

被引:17
作者
Mi, WD [1 ]
Sakai, T [1 ]
Kudo, T [1 ]
Kudo, M [1 ]
Matsuki, A [1 ]
机构
[1] Hirosaki Univ, Sch Med, Dept Anesthesiol, Hirosaki, Aomori 0368563, Japan
关键词
anesthesia; intravenous; anesthesia emergence; bispectral index; drug interaction; fentanyl plasma concentration; propofol;
D O I
10.1016/S0952-8180(02)00510-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To investigate the effect of different plasma levels of fentanyl on the concentration of propofol and the Bispectral Index (BIS) required for patients to regain consciousness and orientation following surgery. Design: Prospective, open-label study. Setting: Operating room of a university hospital. Patients: 28 patients, aging 20 to 50 years, scheduled for elective, 1- to 4-hour surgeries under general anesthesia. Interventions: BIS was continuously monitored from bifrontal montage (At1-Fpz and At2-Fpz) using an Aspect A-1, 050 EEG system (Aspect, Natick, MA). Anesthesia was induced with bolus injections of fentanyl 2 mug/kg and propofol 2 mg/kg, and maintained with intermittent injections of fentanyl and constant infusion of propofol. Propofol infusion was stopped at the end of surgery. Measurements: Consciousness and orientation were assessed as clinical endpoints once every 2 minutes following the end of the surgery. Blood samples were extracted for plasma prapofol and fentanyl concentrations (PCp and FCp, respectively), and BIS values were recorded when patients regained consciousness and orientation. Patients were allocated to one of three groups depending on FCp on awakening. Group 1, FCp > 1 mug/L (n = 8); Group 2, FCp < 1 mug/L and >0.45 mug/L (n = 9); and Group 3, FCp < 0.45 mug/L (n = 11). PCp, BIS, recovery time, and other data were compared between the three groups. Main Results: Demographic values, duration of surgery, and consumption of propofol and fentanyl were not different between the three groups. Group 3 patients regained consciousness with significantly higher propofol concentration (mean PCp = 3.2 mg/L) compared with those in Groups 1 and 2 (p < 0.05). However, the BIS values at both recovery endpoints were not different among the three groups. Conclusions: The plasma levels of fentanyl affect the concentrations of propofol required for patients to regain consciousness. The BIS values for wakefulness are unaltered at the different combinations of propofol and fentanyl concentrations. Thus, the BIS appears to be a useful and consistent indicator for level of consciousness during emergence from propofol/fentanyl intravenous anesthesia. (C) 2003 by Elsevier Science Inc.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 15 条
[1]   Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (02) :180-184
[2]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[3]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[4]  
HOWELL S, 1995, ANESTHESIOLOGY, V83, pA367
[5]   PROPOFOL BLOOD-CONCENTRATION AND THE BISPECTRAL INDEX PREDICT SUPPRESSION OF LEARNING DURING PROPOFOL EPIDURAL-ANESTHESIA IN VOLUNTEERS [J].
LESLIE, K ;
SESSLER, DI ;
SCHROEDER, M ;
WALTERS, K .
ANESTHESIA AND ANALGESIA, 1995, 81 (06) :1269-1274
[6]   Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation [J].
Liu, J ;
Singh, H ;
White, PF .
ANESTHESIA AND ANALGESIA, 1997, 84 (01) :185-189
[7]  
Mi W. D., 1999, European Journal of Anaesthesiology, V16, P47, DOI 10.1046/j.1365-2346.1999.00421.x
[8]   OPIOID SUPPLEMENTATION DURING PROPOFOL ANESTHESIA - THE EFFECTS OF FENTANYL OR ALFENTANIL ON PROPOFOL ANESTHESIA IN DAYCASE SURGERY [J].
MOFFAT, AC ;
MURRAY, AW ;
FITCH, W .
ANAESTHESIA, 1989, 44 (08) :644-647
[9]   A primer for EEG signal processing in anesthesia [J].
Rampil, IJ .
ANESTHESIOLOGY, 1998, 89 (04) :980-1002
[10]  
ROBERTS FL, 1988, ANAESTHESIA, V43, pS14