Cardiac and respiratory MRI gating using combined wavelet sub-band decomposition and adaptive filtering

被引:17
作者
Abi-Abdallah, Dima
Drochon, Agnes
Robin, Vincent
Fokapu, Odette
机构
[1] Univ Technol Compiegne, UMR Biomecan & Genie Biomed 6600, CNRS, Lab Biomecan & Genie Biomed, F-60205 Compiegne, France
[2] Univ Technol Compiegne, Lab Math Appl, F-60206 Compiegne, France
[3] Univ Picardie Jules Verne, IUT Aisne, Amiens, France
关键词
ECG; RLS; filter banks; real time synchronization;
D O I
10.1007/s10439-007-9285-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiac Magnetic Resonance Imaging (MRI) requires synchronization to overcome motion related artifacts caused by the heart's contractions and the chest wall movements during respiration. Achieving good image quality necessitates combining cardiac and respiratory gating to produce, in real time, a trigger signal that sets off the consecutive image acquisitions. This guarantees that the data collection always starts at the same point of the cardiac cycle during the exhalation phase. In this paper, we present a real time algorithm for extracting a cardiac-respiratory trigger signal using only one, adequately placed, ECG sensor. First, an off-line calculation phase, based on wavelet decomposition, is run to compute an optimal QRS filter. This filter is used, afterwards, to accomplish R peak detection, while a low pass filtering process allows the retrieval of the respiration cycle. The algorithm's synchronization capabilities were assessed during mice cardiac MRI sessions employing three different imaging sequences, and three specific wavelet functions. The prominent image enhancement gave a good proof of correct triggering. QRS detection was almost flawless for all signals. As for the respiration cycle retrieval it was evaluated on contaminated simulated signals, which were artificially modulated to imitate respiration. The results were quite satisfactory.
引用
收藏
页码:733 / 743
页数:11
相关论文
共 17 条
[1]   Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates [J].
Abächerli, R ;
Pasquier, C ;
Odille, F ;
Kraemer, M ;
Schmid, JJ ;
Felblinger, J .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (01) :41-50
[2]   Reference signal extraction from corrupted ECG using wavelet decomposition for MRI sequence triggering: application to small animals [J].
Abi-Abdallah, Dima ;
Chauvet, Eric ;
Bouchet-Fakri, Latifa ;
Bataillard, Alain ;
Briguet, Andre ;
Fokapu, Odette .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[3]   ECG beat detection using filter banks [J].
Afonso, VX ;
Tompkins, WJ ;
Nguyen, TQ ;
Luo, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (02) :192-202
[4]   Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields [J].
Cassidy, PJ ;
Schneider, JE ;
Grieve, SM ;
Lygate, C ;
Neubauer, S ;
Clarke, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :229-237
[5]  
DAMJI AA, 1988, MAGN RESON MED, V6, P89
[6]  
Felblinger J, 1999, MAGN RESON MED, V41, P715, DOI 10.1002/(SICI)1522-2594(199904)41:4<715::AID-MRM9>3.0.CO
[7]  
2-7
[8]   Amplitude demodulation of the electrocardiogram signal (ECG) for respiration monitoring and compensation during MR examinations [J].
Felblinger, J ;
Boesch, C .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :129-136
[9]   ELECTROCARDIOGRAM ACQUISITION DURING MR EXAMINATIONS FOR PATIENT MONITORING AND SEQUENCE TRIGGERING [J].
FELBLINGER, J ;
LEHMANN, C ;
BOESCH, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) :523-529
[10]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO