A Real-Time Localization System for an Endoscopic Capsule Using Magnetic Sensors

被引:56
作者
Duc Minh Pham [1 ]
Aziz, Syed Mahfuzul [1 ]
机构
[1] Univ S Australia, Sch Engn, Mawson Lakes, SA 5095, Australia
基金
澳大利亚研究理事会;
关键词
in vivo tracking; magnetic localization system; real-time tracking; gastrointestinal tract; endoscopic capsule; ALGORITHM;
D O I
10.3390/s141120910
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetic sensing technology offers an attractive alternative for in vivo tracking with much better performance than RF and ultrasound technologies. In this paper, an efficient in vivo magnetic tracking system is presented. The proposed system is intended to localize an endoscopic capsule which delivers biomarkers around specific locations of the gastrointestinal (GI) tract. For efficiently localizing a magnetic marker inside the capsule, a mathematical model has been developed for the magnetic field around a cylindrical magnet and used with a localization algorithm that provides minimum error and fast computation. The proposed tracking system has much reduced complexity compared to the ones reported in the literature to date. Laboratory tests and in vivo animal trials have demonstrated the suitability of the proposed system for tracking a magnetic marker with expected accuracy.
引用
收藏
页码:20910 / 20929
页数:20
相关论文
共 29 条
[1]  
AIHW, AUSTR HLTH REP 2011
[2]  
Aziz S. M., 2008, REAL TIME TRACKING S, V20, P201
[3]   Energy Efficient Image Transmission in Wireless Multimedia Sensor Networks [J].
Aziz, Syed Mahfuzul ;
Duc Minh Pham .
IEEE COMMUNICATIONS LETTERS, 2013, 17 (06) :1084-1087
[4]   Global Optimization of Costly Nonconvex Functions Using Radial Basis Functions [J].
Bjorkman, Mattias ;
Holmstrom, Kenneth .
OPTIMIZATION AND ENGINEERING, 2000, 1 (04) :373-397
[5]   The dependence of magnetic properties and hot workability of rare earth-iron-boride magnets upon composition [J].
Brown, DN ;
Smith, B ;
Ma, BM ;
Campbell, P .
IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) :2895-2897
[6]   Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz [J].
Chirwa, LC ;
Hammond, PA ;
Roy, S ;
Cumming, DRS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :484-492
[7]  
Greer J. B., 2012, EPIDEMIOLOGY GASTROI, P49
[8]  
Hu C, 2005, 2005 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, P3365
[9]   Sensor arrangement optimization of magnetic localization and orientation system [J].
Hu, Chao ;
Ma, Tongxing ;
Meng, Max Q. -H. .
2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATION TECHNOLOGY, PROCEEDINGS, 2007, :311-+
[10]   The calibration of 3-axis magnetic sensor array system for tracking wireless capsule endoscope [J].
Hu, Chao ;
Meng, Max Q. -H. ;
Mandal, Mrinal .
2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, 2006, :162-+