摘要
The use of passive harmonic filters (PHFs) in an electrical system is in most cases for the fundamental harmonic reactive power compensation and harmonics mitigation. In comparison to other filters applied to improve the power quality, such as the shunt active power filter or hybrid active power filter, their main advantages are the low investment costs and easy applicability in low-, medium-, and high-voltage electrical systems. However, their installation demands a deep analysis of the electrical system as well as a thorough knowledge of the topology to be installed. Their work efficiency is influenced by the parameters of the electrical system (grid, load, and filter itself) which must be well-known before installation. The aim of this paper is to present an investigation on the work efficiency of the LC passive harmonic filter chosen topologies. The PHFs are investigated in the frequency domain through their impedance versus frequency characteristics as well as in the time domain through an electrical system. A comparative study between filters is also considered. The investigations on the case examples of PHFs are based on simulations and some laboratory studies are also presented.
引用
收藏
页数:35
相关论文
共 77 条
[11]  
Antonio M., 2011, POWER QUALITY
[12]  
Arrillaga J., 1985, POWER SYSTEM HARMONI
[13]  
Badave S.M., 2016, P 1 IEEE INT C POW E
[14]   Optimal Design of C-type Passive Filters Based on Response Surface Methodology for Typical Industrial Power Systems [J].
Balci, Murat Erhan ;
Karaoglan, Aslan Deniz .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (07) :653-668
[15]  
Bhim SinghAmbrish Chandra., 2015, Power Quality: Problems and Mitigation Techniques, V1st
[16]   CONTROLLING HARMONIC INSTABILITY OF HVDC LINKS CONNECTED TO WEAK AC SYSTEMS [J].
BODGER, PS ;
IRWIN, GD ;
WOODFORD, DA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (04) :2039-2046
[17]   Optimal multiobjective planning of large-scale passive harmonic filters using hybrid differential evolution method considering parameter and loading uncertainty [J].
Chang, YP ;
Wu, CJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) :408-416
[18]  
Chiang S. J., 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321), P406, DOI 10.1109/PESC.1999.789037
[19]  
Cho Y.-S, 2011, J INT COUNCIL ELECT, V1, P7, DOI [10.5370/JICEE.2011.1.1.007, DOI 10.5370/JICEE.2011.1.1.007]
[20]   Optimal planning of large passive-harmonic-filters set at high voltage level [J].
Chou, CJ ;
Liu, CW ;
Lee, JY ;
Lee, KD .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (01) :433-441