Dynamic design theory and application of large vibrating screen

被引:50
作者
Zhao Yue-min [1 ]
Liu Chu-sheng [1 ]
He Xiao-mei [1 ]
Zhang Cheng-yong [1 ]
Wang Yi-bin [2 ]
Ren Zi-ting [3 ]
机构
[1] China Univ Min & Technol, Sch Chem Engn & Technol, Xuzhou 221116, Peoples R China
[2] Yangquan Coal Grp Co Ltd, Yangquan 045000, Peoples R China
[3] Huayue Machine Co Ltd, Yangquan 045008, Peoples R China
来源
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MINING SCIENCE & TECHNOLOGY (ICMST2009) | 2009年 / 1卷 / 01期
基金
中国国家自然科学基金;
关键词
large vibrating screen; reliability; hyperstatic net-beam structure; finite element; dynamic optimization;
D O I
10.1016/j.proeps.2009.09.123
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The reliability is a key factor for the design and manufacture of large vibrating screen. In the paper, we presented a new large vibrating screen with hyperstatic net-beam structure. Dynamic characteristic of the vibrating screen was researched and dynamic simulation method of large screening machines was explored. We used finite element method (FEM) to analyze dynamic characteristic of large vibrating screen with hyperstatic net-beam structure. Multi natural frequency, natural modes of vibration and dynamic response of the vibrating screen were calculated. The structural size of stiffeners on the side plate was optimized under multiple frequencies constraints and an adaptive optimization criterion was given. The results show that the vibrating screen's structural strength is increased and the natural frequency of bending deformation is enhanced. The modal frequencies are far from working frequency, and thus the structure is able to avoid resonance effectively and reduce the destructiveness. The maximum transverse displacement of the vibrating screen is 0.13 mm, the maximum difference in vibration amplitude of corresponding points is 0.44mm and the maximum dynamic stress is 16.63MPa. The structural optimization shows that the mass of the side plate is decreased by 194.50kg, the second and third modal frequency is increased by 1.73% and 2.91% respectively and a better optimal effect is received.
引用
收藏
页码:776 / 784
页数:9
相关论文
共 15 条
[1]  
DU P, 2004, PRINCIPLE MODEL APPL
[2]   STRUCTURAL OPTIMIZATION WITH FREQUENCY CONSTRAINTS [J].
GRANDHI, RV ;
VENKAYYA, VB .
AIAA JOURNAL, 1988, 26 (07) :858-866
[3]  
Heylen W., 1999, Modal analysis: theory and testing
[4]  
[焦红光 JIAO Hongguang], 2006, [中国矿业大学学报. 自然科学版, Journal of China University of Mining & Technology. Natural science], V35, P384
[5]  
Khoury D. L., 1981, COAL CLEANING TECHNO
[6]  
LI H, 2006, VIBRATION THEORY ENG
[7]  
LIU W, 1994, OPTIMAL DESIGN MACHI
[8]  
Ma F., 1996, COAL MINE MACHINERY, V6, P40
[9]  
WANG F, 1989, COAL MINE MACHINERY, V10, P41
[10]  
WANG R, 2003, P 5 INT S TEST MEAS