Keratometry with five different techniques: a study of device repeatability and inter-device agreement

被引:27
作者
Mehravaran, Shiva
Asgari, Soheila
Bigdeli, Sara
Shahnazi, Ashkan
Hashemi, Hassan
机构
[1] Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, 96 Esfandiar Blvd., Vali'asr Ave.
关键词
ANTERIOR-CHAMBER DEPTH; PARTIAL COHERENCE INTERFEROMETRY; CORNEAL REFRACTIVE SURGERY; INTRAOCULAR-LENS POWER; AXIAL LENGTH; CLINICAL-EVALUATION; OCULAR BIOMETRY; EYES; TOPOGRAPHY; CURVATURE;
D O I
10.1007/s10792-013-9895-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to determine and compare the repeatability of keratometry measurements with the Javal manual keratometer, Topcon automated kerato-refractometer, IOLMaster, EyeSys Corneal Analysis System, and Pentacam Scheimpflug Topography System, and determine the agreement of measurements of the latter four devices with the Javal keratometer as the gold standard. In this crosssectional study, 21 people with no history of ocular disease or surgery were examined twice with each device. Minimum, maximum, and average keratometry readings were recorded in diopters (D) for each eye and used in the analyses. For statistical analysis, we determined correlation coefficients and used the Bland-Altman method and calculated the 95 % limits of agreement (LoA). All repeatability coefficients were satisfactorily high. Best repeatability for minimum keratometry and maximum keratometry readings was seen with IOLMaster (95 % LoA -0.23 to 0.19 D and-0.31 to 0.32 D, respectively). Agreement with Javal manual keratometry was best with Topcon and IOLMaster for minimum keratometry readings (95 % LoA -0.67 to 0.28 D and -0.57 to 0.38 D, respectively), and with Topcon for maximum keratometry readings (95 % LoA -0.85 to 0.63 D). In our series of normal eyes, keratometry readings with Topcon, IOLMaster, and Pentacam showed very good agreement with Javal measurements, and inter-device agreements were better than the repeatability of the manual gold standard. However, differences between Javal and EyeSys may not be clinically acceptable, and these two devices should not be used interchangeably. Further studies are needed to investigate these issues in non-virgin eyes.
引用
收藏
页码:869 / 875
页数:7
相关论文
共 41 条
[1]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Chang Minwook, 2012, Korean J Ophthalmol, V26, P10, DOI 10.3341/kjo.2012.26.1.10
[4]   Evaluation of the EyeSys model II computerized videokeratoscope. Part II: The repeatability and accuracy in measuring convex aspheric surfaces [J].
Dave, T ;
Ruston, D ;
Fowler, C .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (09) :656-662
[5]   Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K autorefractor [J].
Davies, LN ;
Mallen, EAH ;
Wolffsohn, JS ;
Gilmartin, B .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (04) :320-324
[6]   Comparison of different techniques of anterior chamber depth and keratometric measurements [J].
Elbaz, Uri ;
Barkana, Yaniv ;
Gerber, Yariv ;
Avni, Isaac ;
Zadok, David .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (01) :48-53
[8]  
Giraldez MJ, 2000, INT CONTACT LENS CLI, V27, P33
[9]   Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula [J].
Haigis, Wolfgang .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1658-1663
[10]   Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle [J].
Hashemi, Hassan ;
Mehravaran, Shiva ;
Rezvan, Farhad .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (01) :67-70