Characterisation of CVD diamond dosimeters in on-line configuration

被引:34
作者
Bruzzi, M
Bucciolini, M
Cirrone, GAP
Cuttone, G
Mazzocchi, S
Pirollo, S
Sciortino, S
机构
[1] Ist Nazl Fis Nucl, Sez Firenze, I-50125 Florence, Italy
[2] Univ Florence, Dipartimento Energet, I-50139 Florence, Italy
[3] Univ Florence, Dipartimento Fisiopatol Clin, Florence, Italy
[4] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95100 Catania, Italy
[5] Ctr Siciliano Fis Nucl Struttura Mat, Catania, Italy
关键词
chemical vapor deposition; electron dosimetry; photon dosimetry; solid state detectors;
D O I
10.1016/S0168-9002(00)00816-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high sensitivity and the nearly tissue equivalence of diamond make it a material suitable as detector for on-line dosimetry. The tremendous development of the CVD diamond technology allows to employ polycrystalline diamond films with controlled dimensions and a potential low cost as on-line radiation dosimeters. In this paper a characterisation and a comparison of the response of two "detector-grade" CVD diamond films under photon and electron beams are presented. The results show that both samples can be used as on-line dosimeters for applications in radiotherapy. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 11 条
[1]  
BACCI T, 1997, MAT SCI ENG B-SOLID, V47, P56
[2]  
Fowler J, 1966, RADIAT DOSIM, V2, P290
[3]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229
[4]   SYNTHETIC DIAMONDS AS IONIZATION-CHAMBER RADIATION DETECTORS IN BIOLOGICAL ENVIRONMENTS [J].
KEDDY, RJ ;
NAM, TL ;
BURNS, RC .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :751-759
[5]   A diamond detector in the dosimetry of high-energy electron and photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2183-2192
[6]   Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nusslin, F .
MEDICAL PHYSICS, 1997, 24 (04) :535-536
[7]   Growth and characterisation of CVD diamond wires for x-ray detection [J].
Manfredotti, C ;
Fizzotti, F ;
LoGiudice, A ;
Mucera, G ;
Polesello, P ;
Vittone, E ;
Mankelevich, YA ;
Suetin, NV .
DIAMOND AND RELATED MATERIALS, 1997, 6 (08) :1051-1056
[8]   EVALUATION OF DIAMOND RADIATION DOSIMETERS [J].
PLANSKOY, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (03) :519-532
[9]   EVALUATION OF THE DOSIMETRIC CHARACTERISTICS OF A DIAMOND DETECTOR FOR PHOTON-BEAM MEASUREMENTS [J].
RUSTGI, SN .
MEDICAL PHYSICS, 1995, 22 (05) :567-570
[10]   APPLICATION OF SOLID-STATE DETECTORS FOR DOSIMETRY OF THERAPEUTIC PROTON-BEAMS [J].
VATNITSKY, S ;
MILLER, D ;
SIEBERS, J ;
MOYERS, M .
MEDICAL PHYSICS, 1995, 22 (04) :469-473