Quantifying errors in flow measurement using phase contrast magnetic resonance imaging: comparison of several boundary detection methods

被引:33
|
作者
Jiang, Jing [1 ,4 ]
Kokeny, Paul [1 ,5 ]
Ying, Wang [1 ,2 ]
Magnano, Chris [3 ]
Zivadinov, Robert [3 ]
Haacke, E. Mark [1 ,4 ,5 ,6 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI USA
[2] Northeastern Univ, Coll Informat Sci & Engn, Shenyang, Liaoning Provin, Peoples R China
[3] SUNY Buffalo, Buffalo Neuroimaging Anal Ctr, Buffalo, NY 14260 USA
[4] Wayne State Univ, Dept Radiol, Detroit, MI USA
[5] Magnet Resonance Innovat Inc, Detroit, MI 48202 USA
[6] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Vessel segmentation; Flow quantification; Flow error; VESSEL AREA; BLOOD-FLOW; VELOCITY DATA; ACCURACY; PRECISION; MRI; QUANTIFICATION; PARAMETERS; VEINS;
D O I
10.1016/j.mri.2014.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantifying flow from phase-contrast MRI (PC-MRI) data requires that the vessels of interest be segmented. The estimate of the vessel area will dictate the type and magnitude of the error sources that affect the flow measurement. These sources of errors are well understood, and mathematical expressions have been derived for them in previous work. However, these expressions contain many parameters that render them difficult to use for making practical error estimates. In this work, some realistic assumptions were made that allow for the simplification of such expressions in order to make them more useful. These simplified expressions were then used to numerically simulate the effect of segmentation accuracy and provide some criteria that if met, would keep errors in flow quantification below 10% or 5%. Four different segmentation methods were used on simulated and phantom MRA data to verify the theoretical results. Numerical simulations showed that including partial volumed edge pixels in vessel segmentation provides less error than missing them. This was verified with MRA simulations, as the best performing segmentation method generally included such pixels. Further, it was found that to obtain a flow error of less than 10% (5%), the vessel should be at least 4 (5) pixels in diameter, have an SNR of at least 10:1 and have a peak velocity to saturation cut-off velocity ratio of at least 5:3. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [31] Cervical compressive myelopathy: flow analysis of cerebrospinal fluid using phase-contrast magnetic resonance imaging
    Yun Jung Bae
    Joon Woo Lee
    Eugene Lee
    Jin S. Yeom
    Ki-Jeong Kim
    Heung Sik Kang
    European Spine Journal, 2017, 26 : 40 - 48
  • [32] Importance of complex blood flow in the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging
    Truedsson, Frida
    Polte, Christian L.
    Gao, Sinsia A.
    Johnsson, Ase A.
    Bech-Hanssen, Odd
    Lagerstrand, Kerstin M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (12) : 3561 - 3572
  • [33] Quantification of pulmonary microcirculation by dynamic contrast-enhanced magnetic resonance imaging: Comparison of four regularization methods
    Ravesh, M. Salehi
    Brix, G.
    Laun, F. B.
    Kuder, T. A.
    Puderbach, M.
    Ley-Zaporozhan, J.
    Ley, S.
    Fieselmann, A.
    Herrmann, M. F.
    Schranz, W.
    Semmler, W.
    Risse, F.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 188 - 199
  • [34] Magnetic resonance imaging of endolymphatic hydrops: a comparison of methods with and without gadolinium-based contrast agent administration
    Ohashi, Toshio
    Naganawa, Shinji
    Nasu, Yusuke
    Kuno, Kayao
    Kato, Katsuhiko
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2023, 85 (02): : 299 - 309
  • [35] Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging
    Yokosawa, S
    Nakamura, M
    Wada, S
    Isoda, H
    Takeda, H
    Yamaguchi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 459 - 467
  • [36] Measurement of an oil-water flow using magnetic resonance imaging
    Lakshmanan, Susithra
    Maru, Wessenu A.
    Holland, Daniel J.
    Mantle, Mick D.
    Sederman, Andy J.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 161 - 171
  • [37] Quantification of cerebrospinal fluid flow in dogs by cardiac-gated phase-contrast magnetic resonance imaging
    Christen, Muriel A.
    Schweizer-Gorgas, Daniela
    Richter, Henning
    Joerger, Fabiola B.
    Dennler, Matthias
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (01) : 333 - 340
  • [38] Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
    Machado, Priscilla
    Tan, Allison
    Forsberg, Flemming
    Gonsalves, Carin F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03) : 394 - 398
  • [39] Myocardial blood flow estimates from dynamic contrast-enhanced magnetic resonance imaging: three quantitative methods
    Borrazzo, Cristian
    Galea, Nicola
    Pacilio, Massimiliano
    Altabella, Luisa
    Preziosi, Enrico
    Carni, Marco
    Ciolina, Federica
    Vullo, Francesco
    Francone, Marco
    Catalano, Carlo
    Carbone, Iacopo
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
  • [40] The measurement of tibial torsion by magnetic resonance imaging in children: the comparison of three different methods
    Basaran S.H.
    Ercin E.
    Bayrak A.
    Cumen H.
    Bilgili M.G.
    Inci E.
    Avkan M.C.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1327 - 1332