Quantifying errors in flow measurement using phase contrast magnetic resonance imaging: comparison of several boundary detection methods

被引:33
|
作者
Jiang, Jing [1 ,4 ]
Kokeny, Paul [1 ,5 ]
Ying, Wang [1 ,2 ]
Magnano, Chris [3 ]
Zivadinov, Robert [3 ]
Haacke, E. Mark [1 ,4 ,5 ,6 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI USA
[2] Northeastern Univ, Coll Informat Sci & Engn, Shenyang, Liaoning Provin, Peoples R China
[3] SUNY Buffalo, Buffalo Neuroimaging Anal Ctr, Buffalo, NY 14260 USA
[4] Wayne State Univ, Dept Radiol, Detroit, MI USA
[5] Magnet Resonance Innovat Inc, Detroit, MI 48202 USA
[6] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Vessel segmentation; Flow quantification; Flow error; VESSEL AREA; BLOOD-FLOW; VELOCITY DATA; ACCURACY; PRECISION; MRI; QUANTIFICATION; PARAMETERS; VEINS;
D O I
10.1016/j.mri.2014.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantifying flow from phase-contrast MRI (PC-MRI) data requires that the vessels of interest be segmented. The estimate of the vessel area will dictate the type and magnitude of the error sources that affect the flow measurement. These sources of errors are well understood, and mathematical expressions have been derived for them in previous work. However, these expressions contain many parameters that render them difficult to use for making practical error estimates. In this work, some realistic assumptions were made that allow for the simplification of such expressions in order to make them more useful. These simplified expressions were then used to numerically simulate the effect of segmentation accuracy and provide some criteria that if met, would keep errors in flow quantification below 10% or 5%. Four different segmentation methods were used on simulated and phantom MRA data to verify the theoretical results. Numerical simulations showed that including partial volumed edge pixels in vessel segmentation provides less error than missing them. This was verified with MRA simulations, as the best performing segmentation method generally included such pixels. Further, it was found that to obtain a flow error of less than 10% (5%), the vessel should be at least 4 (5) pixels in diameter, have an SNR of at least 10:1 and have a peak velocity to saturation cut-off velocity ratio of at least 5:3. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Measurement of hepatic arterial flow using phase contrast magnetic resonance imaging
    Wilson, Daniel J.
    Ridgway, John P.
    Evans, J. Anthony
    Robinson, Philip
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) : N439 - N449
  • [2] Wall Shear Stress Measurement Using Phase Contrast Magnetic Resonance Imaging With Phase Contrast Magnetic Resonance Angiography in Arteriovenous Polytetrafluoroethylene Grafts
    Misra, Sanjay
    Fu, Alex A.
    Misra, Khamal D.
    Glockner, James F.
    Mukhopadhyay, Debabrata
    ANGIOLOGY, 2009, 60 (04) : 441 - 447
  • [3] Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography
    Khan, Muhammad Ayaz
    Liu, Jie
    Tarumi, Takashi
    Lawley, Justin Stevan
    Liu, Peiying
    Zhu, David C.
    Lu, Hanzhang
    Zhang, Rong
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (02) : 541 - 549
  • [4] The clinical impact of phase offset errors and different correction methods in cardiovascular magnetic resonance phase contrast imaging: a multi-scanner study
    Minderhoud, Savine C. S.
    van der Velde, Nikki
    Wentzel, Jolanda J.
    van der Geest, Rob J.
    Attrach, Mohammed
    Wielopolski, Piotr A.
    Budde, Ricardo P. J.
    Helbing, Willem A.
    Roos-Hesselink, Jolien W.
    Hirsch, Alexander
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [5] Cardiac Flow Analysis Applied to Phase Contrast Magnetic Resonance Imaging of the Heart
    Wong, Kelvin K. L.
    Kelso, Richard M.
    Worthley, Stephen G.
    Sanders, Prashanthan
    Mazumdar, Jagannath
    Abbott, Derek
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (08) : 1495 - 1515
  • [6] Quantitative Analysis of Cerebrospinal Fluid Flow in Complex Regions by Using Phase Contrast Magnetic Resonance Imaging
    Florez, Natalia
    Bouzerar, Roger
    Moratal, David
    Meyer, Marc-Etienne
    Marti-Bonmati, Luis
    Baledent, Olivier
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2011, 21 (03) : 290 - 297
  • [7] Pulsatile cerebrospinal fluid flow measurement using phase-contrast magnetic resonance imaging in patients with cervical myelopathy
    Shibuya, R
    Yonenobu, K
    Koizumi, T
    Kato, Y
    Mitta, M
    Yoshikawa, H
    SPINE, 2002, 27 (10) : 1087 - 1093
  • [8] Improving the Magnetic Resonance Imaging Contrast and Detection Methods with Engineered Magnetic Nanoparticles
    Huang, Jing
    Zhong, Xiaodong
    Wang, Liya
    Yang, Lily
    Mao, Hui
    THERANOSTICS, 2012, 2 (01): : 86 - 102
  • [9] Velocity and volume flow rate measurements using phase contrast magnetic resonance imaging
    Korosec, FR
    Turski, PA
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (04): : 293 - 318
  • [10] A New Method for Quantifying Abdominal Aortic Wall Shear Stress Using Phase Contrast Magnetic Resonance Imaging and the Womersley Solution
    Iffrig, Elizabeth
    Timmins, Lucas H.
    El Sayed, Retta
    Taylor, W. Robert
    Oshinski, John N.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (09):