Sequential Determination of Inorganic Cations and Anions in Cerebrospinal Fluid by Microchip Electrophoresis

被引:7
作者
Hradski, Jasna [1 ]
Bodor, Robert [1 ]
Masar, Marian [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Bratislava 84215, Slovakia
关键词
Microchip electrophoresis; Sequential determination; Inorganic ions; Cerebrospinal fluid; CAPILLARY-ZONE-ELECTROPHORESIS; BIOLOGICAL-FLUIDS; ALZHEIMERS-DISEASE; NITRATE; NITRITE; METABOLITES; SEPARATION; MAGNESIUM; AMMONIUM; CALCIUM;
D O I
10.1007/s10337-014-2711-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analysis of inorganic ions in cerebrospinal fluid (CSF) is used mainly in the diagnostics of central nervous system diseases, such as Alzheimer's disease or multiple sclerosis. A new analytical method for fast determination of inorganic cations (ammonium, calcium, magnesium, sodium and potassium) and anions (chloride, sulfate, nitrite and nitrate) in CSF on an electrophoretic microchip was developed in this context. Zone electrophoresis (ZE) separations were performed on the microchip with coupled channels (CC) and contact conductivity detection. Two different propionate background electrolytes were used for the sequential determination of cations at pH 3.1 and anions at pH 4.3. ZE was used for the determination of cationic constituents while ZE-ZE approach was employed for the determination of chloride in the first separation channel on the CC microchip and other anionic micro-constituents in the second channel. LOD values were in the range of 0.003-0.012 mg L-1 and 0.019-0.047 mg L-1 for cations and anions, respectively. Repeatability of migration time was up to 1.2 % for both cations and anions. Repeatability of peak area ranged from 0.3 to 5.6 % for cations and from 0.6 to 6.0 % for anions. Recovery of both cations and anions was in the range 90-106 %. CSF samples were only diluted appropriately without other sample pretreatment prior to analysis. Developed sequential method is suitable for fast determination of the studied cations and anions in CSF with total analysis time < 15 min.
引用
收藏
页码:1461 / 1468
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 2002, Clinical laboratory medicine
[2]  
[Anonymous], IONS PHYS FLUIDS DIO
[3]  
BASUN H, 1991, J NEURAL TRANSM-PARK, V3, P231
[4]  
Becker J. S., 2007, INORGANIC MASS SPECT
[5]   Capillary electrophoretic method for the determination of inorganic and organic anions in real samples -: Strategies for improving repeatability and reproducibility [J].
Blanco-Heras, Gustavo A. ;
Turnes-Carou, Ma Isabel ;
Lopez-Mahia, Purificacion ;
Muniategui-Lorenzo, Soledad ;
Prada-Rodriguez, Dario ;
Fernandez-Fernandez, Esther .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (02) :275-278
[6]  
CIBAGEIGY, 1977, WISSENSCHAFTLICHE TA
[7]   Determination of metabolic organic acids in cerebrospinal fluid by microchip electrophoresis [J].
Danc, Ladislav ;
Bodor, Robert ;
Troska, Peter ;
Horciciak, Michal ;
Masar, Marian .
ELECTROPHORESIS, 2014, 35 (15) :2146-2154
[8]   Guidelines on routine cerebrospinal fluid analysis. Report from an EFNS task force [J].
Deisenhammer, F. ;
Bartos, A. ;
Egg, R. ;
Gilhus, N. E. ;
Giovannoni, G. ;
Rauer, S. ;
Sellebjerg, F. .
EUROPEAN JOURNAL OF NEUROLOGY, 2006, 13 (09) :913-922
[9]   EFFECT OF THE CONCENTRATION OF 18-CROWN-6 ADDED TO THE ELECTROLYTE UPON THE SEPARATION OF AMMONIUM, ALKALI AND ALKALINE-EARTH CATIONS BY CAPILLARY ELECTROPHORESIS [J].
FRANCOIS, C ;
MORIN, P ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :535-553
[10]   Polymeric Microchip for the Simultaneous Determination of Anions and Cations by Hydrodynamic Injection Using a Dual-Channel Sequential Injection Microchip Electrophoresis System [J].
Gaudry, Adam J. ;
Nai, Yi Heng ;
Guij, Rosanne M. ;
Breadmore, Michael C. .
ANALYTICAL CHEMISTRY, 2014, 86 (07) :3380-3388