Impedance Testing on Cochlear Implants After Electroconvulsive Therapy

被引:8
作者
McRackan, Theodore R. [1 ,4 ]
Rivas, Alejandro [1 ,4 ]
Hedley-Williams, Andrea [1 ,4 ]
Raj, Vidya [2 ,5 ]
Dietrich, Mary S. [3 ,6 ]
Clark, Nathaniel K. [2 ,5 ]
Labadie, Robert F. [1 ]
机构
[1] Vanderbilt Univ, Dept Otolaryngol Head Neck Surg, Sch Med, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Psychiat, Sch Med, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Biostat, Sch Med, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Sch Nursing, Dept Otolaryngol Head Neck Surg, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Sch Nursing, Dept Psychiat, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Sch Nursing, Dept Biostat, Nashville, TN 37232 USA
关键词
cochlear implant; electroconvulsive therapy; impedance testing; PATIENT;
D O I
10.1097/YCT.0000000000000124
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objective: Cochlear implants (CI) are neural prostheses that restore hearing to individuals with profound sensorineural hearing loss. The surgically implanted component consists of an electrode array, which is threaded into the cochlea, and an electronic processor, which is buried under the skin behind the ear. The Food and Drug Administration and CI manufacturers contend that electroconvulsive therapy (ECT) is contraindicated in CI recipients owing to risk of damage to the implant and/or the patient. We hypothesized that ECT does no electrical damage to CIs. Methods: Ten functional CIs were implanted in 5 fresh cadaveric human heads. Each head then received a consecutive series of 12 unilateral ECT sessions applying maximum full pulse-width energy settings. Electroconvulsive therapy was delivered contralaterally to 5 CIs and ipsilaterally to 5 CIs. Electrical integrity testing (impedance testing) of the electrode array was performed before and after CI insertion, and after the first, third, fifth, seventh, ninth, and 12th ECT sessions. Electroconvulsive therapy was performed by a staff psychiatrist experienced with the technique. Explanted CIs were sent back to the manufacturer for further integrity testing. Results: No electrical damage was identified during impedance testing. Overall, there were statistically significant decreases in impedances (consistent with no electrical damage) when comparing pre-ECT impedance values to those after 12 sessions. There was no statistically significant difference (P > 0.05) in impedance values comparing ipsilateral to contralateral ECT. Manufacturer testing revealed no other electrical damage to the CIs. Conclusion: Electroconvulsive therapy does not seem to cause any detectable electrical injury to CIs.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [41] COCHLEAR IMPLANTS BIOCOMPATIBILITY
    CHOUARD, CH
    PIALOUX, P
    [J]. BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 1995, 179 (03): : 549 - 555
  • [42] Cochlear implants and tinnitus
    Baguley, David M.
    Atlas, Marcus D.
    [J]. TINNITUS: PATHOPHYSIOLOGY AND TREATMENT, 2007, 166 : 347 - 355
  • [43] COCHLEAR IMPLANTS IN CHINA
    ZENG, FG
    [J]. AUDIOLOGY, 1995, 34 (02): : 61 - 75
  • [44] Cochlear implants and tinnitus
    Olze, H.
    [J]. HNO, 2015, 63 (04) : 291 - 297
  • [45] Electroconvulsive Therapy and Dopa-Responsive Dystonia Improvements in Neurological Symptoms After Electroconvulsive Therapy Treatment
    Guillet, Clement
    Roy, Rudy Didi
    Hussami, Aymard
    Girod, Jean-Claude
    [J]. JOURNAL OF ECT, 2020, 36 (04) : E53 - E54
  • [46] Cochlear Implants in Children
    Auinger, Alice B.
    Gstoettner, Wolfgang
    [J]. PADIATRIE UND PADOLOGIE, 2020, 55 (03): : 128 - 131
  • [47] Tinnitus and cochlear implants
    Bovo, Roberto
    Ciorba, Andrea
    Martini, Alessandro
    [J]. AURIS NASUS LARYNX, 2011, 38 (01) : 14 - 20
  • [48] RADIOLOGY FOR COCHLEAR IMPLANTS
    GRAY, RF
    EVANS, RA
    FREER, CEL
    SZUTOWICZ, HE
    MASKELL, GF
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1991, 105 (02) : 85 - 88
  • [49] Preliminary results of video Head Impulse Testing (vHIT) in children with cochlear implants
    Nassif, Nader
    Balzanelli, Cristiano
    Redaelli de Zinis, Luca Oscar
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 88 : 30 - 33
  • [50] Electroconvulsive Therapy in the Presence of Deep Brain Stimulation Implants: Electric Field Effects
    Deng, Zhi-De
    Hardesty, David E.
    Lisanby, Sarah H.
    Peterchev, Angel V.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 2049 - 2052