Impedance Testing on Cochlear Implants After Electroconvulsive Therapy

被引:8
|
作者
McRackan, Theodore R. [1 ,4 ]
Rivas, Alejandro [1 ,4 ]
Hedley-Williams, Andrea [1 ,4 ]
Raj, Vidya [2 ,5 ]
Dietrich, Mary S. [3 ,6 ]
Clark, Nathaniel K. [2 ,5 ]
Labadie, Robert F. [1 ]
机构
[1] Vanderbilt Univ, Dept Otolaryngol Head Neck Surg, Sch Med, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Psychiat, Sch Med, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Biostat, Sch Med, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Sch Nursing, Dept Otolaryngol Head Neck Surg, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Sch Nursing, Dept Psychiat, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Sch Nursing, Dept Biostat, Nashville, TN 37232 USA
关键词
cochlear implant; electroconvulsive therapy; impedance testing; PATIENT;
D O I
10.1097/YCT.0000000000000124
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objective: Cochlear implants (CI) are neural prostheses that restore hearing to individuals with profound sensorineural hearing loss. The surgically implanted component consists of an electrode array, which is threaded into the cochlea, and an electronic processor, which is buried under the skin behind the ear. The Food and Drug Administration and CI manufacturers contend that electroconvulsive therapy (ECT) is contraindicated in CI recipients owing to risk of damage to the implant and/or the patient. We hypothesized that ECT does no electrical damage to CIs. Methods: Ten functional CIs were implanted in 5 fresh cadaveric human heads. Each head then received a consecutive series of 12 unilateral ECT sessions applying maximum full pulse-width energy settings. Electroconvulsive therapy was delivered contralaterally to 5 CIs and ipsilaterally to 5 CIs. Electrical integrity testing (impedance testing) of the electrode array was performed before and after CI insertion, and after the first, third, fifth, seventh, ninth, and 12th ECT sessions. Electroconvulsive therapy was performed by a staff psychiatrist experienced with the technique. Explanted CIs were sent back to the manufacturer for further integrity testing. Results: No electrical damage was identified during impedance testing. Overall, there were statistically significant decreases in impedances (consistent with no electrical damage) when comparing pre-ECT impedance values to those after 12 sessions. There was no statistically significant difference (P > 0.05) in impedance values comparing ipsilateral to contralateral ECT. Manufacturer testing revealed no other electrical damage to the CIs. Conclusion: Electroconvulsive therapy does not seem to cause any detectable electrical injury to CIs.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [1] Electroconvulsive Therapy After Maxillofacial Metallic Implants
    Freeman, G. Mark, Jr.
    Perry, Matthew T.
    Manatt, George S.
    Cristancho, Pilar
    JOURNAL OF ECT, 2014, 30 (01) : 3 - 4
  • [2] Preserved Cochlear Implant Function After Multiple Electroconvulsive Therapy Treatments
    Jiam, Nicole T.
    Li, Descartes
    Kramer, Kurt
    Limb, Charles J.
    LARYNGOSCOPE, 2021, 131 (05) : E1695 - E1698
  • [3] A Review Electroconvulsive Therapy in Cochlear Implant Patients
    Albertsen, Laerke Noergaard
    Lauridsen, Jesper Krogh
    JOURNAL OF ECT, 2022, 38 (01) : 10 - 12
  • [4] Electroconvulsive Therapy in a Cochlear Implant Patient
    Labadie, Robert F.
    Clark, Nathaniel K.
    Cobb, Cheryl M.
    Benningfield, Margaret M.
    Fuchs, D. Catherine
    OTOLOGY & NEUROTOLOGY, 2010, 31 (01) : 64 - 66
  • [5] Integrity testing of cochlear implants in the awake child
    Cullington, HE
    Clarke, GP
    BRITISH JOURNAL OF AUDIOLOGY, 1997, 31 (04): : 247 - 256
  • [6] Cochlear implant should not be absolute contraindication for electroconvulsive therapy and transcranial magnetic stimulation
    Jensen, Kristian H. Reveles
    Navntoft, Charlotte Amalie
    Sindahl, Camilla Hjortdal
    Caye-Thomasen, Per
    Jorgensen, Martin Balslev
    BRAIN STIMULATION, 2020, 13 (05) : 1464 - 1466
  • [7] Fever as a Side Effect after Electroconvulsive Therapy
    Jo, Young Tak
    Lee, Jungsun
    Joo, Yeon Ho
    NEUROPSYCHOBIOLOGY, 2022, 81 (01) : 19 - 27
  • [8] Mortality after electroconvulsive therapy
    Watts, Bradley, V
    Peltzman, Talya
    Shiner, Brian
    BRITISH JOURNAL OF PSYCHIATRY, 2021, 219 (05) : 588 - 593
  • [9] Magnetic resonance imaging after cochlear implants
    Bawazeer, Naif
    Vuong, Hella
    Riehm, Sophie
    Veillon, Francis
    Charpiot, Anne
    JOURNAL OF OTOLOGY, 2019, 14 (01) : 22 - 25
  • [10] Magnetic resonance imaging after cochlear implants
    Naif Bawazeer
    Hella Vuong
    Sophie Riehm
    Francis Veillon
    Anne Charpiot
    JournalofOtology, 2019, 14 (01) : 22 - 25