Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences

被引:14
作者
Bignozzi, Simone [1 ,2 ]
Zaffagnini, Stefano [1 ]
Akkawi, Ibrahim [1 ,2 ]
Marko, Tedi [1 ,2 ]
Bruni, Danilo [1 ,2 ]
Neri, Maria Pia [1 ,2 ]
Colle, Francesca [2 ,3 ,4 ]
Marcacci, Maurilio [1 ,2 ,3 ]
机构
[1] Ist Ortoped Rizzoli, Lab Biomeccan & Innovaz Tecnol, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Lab Biomeccan & Innovaz Tecnol, Clin Ortoped & Traumatol 2, I-40136 Bologna, Italy
[3] Ist Ortoped Rizzoli, Lab NanoBiotecnol NaBi, I-40136 Bologna, Italy
[4] Scuola Super Sant Anna, Biorobot Inst, Pisa, Italy
关键词
Total knee arthroplasty; Postero-stabilized knee; Antero-stabilized knee; Kinematics; Navigation; TOTAL KNEE ARTHROPLASTY; IN-VIVO KINEMATICS; OSTEOARTHRITIC KNEES; WEIGHT-BEARING; NAVIGATION SYSTEM; FEMORAL ROLLBACK; REPLACEMENTS; STABILITY; ROTATION; LOADS;
D O I
10.1007/s00167-014-3200-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up. Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90A degrees flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up. There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs. Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years. III.
引用
收藏
页码:3113 / 3120
页数:8
相关论文
共 41 条
[1]   Comparing navigation-based in vivo knee kinematics pre- and postoperatively between a cruciate-retaining and a cruciate-substituting implant [J].
Baier, Clemens ;
Springorum, Hans-Robert ;
Goetz, Juergen ;
Schaumburger, Jens ;
Luering, Christian ;
Grifka, Joachim ;
Beckmann, Johannes .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (03) :407-414
[2]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[3]   Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements [J].
Belvedere, C. ;
Tamarri, S. ;
Notarangelo, D. P. ;
Ensini, A. ;
Feliciangeli, A. ;
Leardini, A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2375-2383
[4]   Accuracy, Reliability, and Repeatability of Navigation Systems in Clinical Practice [J].
Bignozzi, Simone ;
Lopomo, Nicola ;
Zaffagnini, Stefano ;
Martelli, Sandra ;
Bruni, Danilo ;
Marcacci, Maurilio .
OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2008, 18 (03) :154-157
[5]   Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm [J].
Browne, C ;
Hermida, JC ;
Bergula, A ;
Colwell, CW ;
D'Lima, DD .
KNEE, 2005, 12 (02) :81-88
[6]   Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system [J].
Casino, Daniela ;
Zaffagnini, Stefano ;
Martelli, Sandra ;
Lopomo, Nicola ;
Bignozzi, Simone ;
Iacono, Francesco ;
Russo, Alessandro ;
Marcacci, Maurilio .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) :369-373
[7]   The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty [J].
Churchill, DL ;
Incavo, SJ ;
Johnson, CC ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :909-918
[8]  
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[9]   Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[10]  
Dennis Douglas A, 2005, Instr Course Lect, V54, P207