Ultrasound-Guided Ganglion Impar Block: A Technical Report

被引:31
作者
Lin, Chia-Shiang [2 ,3 ]
Cheng, Jen-Kun [2 ,3 ,4 ]
Hsu, Yung-Wei [2 ,3 ]
Chen, Chien-Chuan [2 ,3 ]
Lao, Hsuan-Chih [2 ,3 ]
Huang, Chun-Jen [2 ,3 ]
Cheng, Peter H. [5 ]
Narouze, Samer [1 ]
机构
[1] Cleveland Clin, Pain Management Dept, Cleveland, OH 44106 USA
[2] Mackay Mem Hosp, Dept Anesthesiol, Taipei, Taiwan
[3] Nursing & Management Coll, Taipei, Taiwan
[4] Taipei Med Univ, Dept Anesthesiol, Taipei, Taiwan
[5] Kaiser Permanente, Riverside Med Ctr, Dept Anesthesiol, Riverside, CA USA
关键词
Ultrasound; Ganglion Impar Block; Sacrococcygeal Approach;
D O I
10.1111/j.1526-4637.2010.00797.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives. Ganglion impar block is an uncommon procedure that has been performed traditional with fluoroscopy. One approach is the trans-sacrococcygeal approach. Sometimes this can be difficult because the sacrococcygeal joint (SCJ) cannot be readily seen on anteroposterior (AP) and lateral fluoroscopy. This technical report describes the feasibility of ultrasound in assisting ganglion impar blocks. Methods. We performed ganglion impar block using ultrasound as the primary imaging tool, with fluoroscopic confirmation in 15 patients. We used a linear array transducer (5-12 MHz) to obtain sonographic transverse and longitudinal views at the sacral cornua; we identified the first cleft below the sacral hiatus as the SCJ. Then we inserted a 23-gauge (7 cm in length) needle into the SCJ under sonographic guidance. Then we confirmed proper needle depth by lateral fluoroscopy and injection of contrast agent. Results. In all 15 procedures, we accurately located and passed the needle into the patients' SCJs under real time sonographic guidance. Conclusions. In cases where the cleft cannot be readily seen on AP and lateral fluoroscopy, we have found ultrasound to be of assistance. Ultrasound does not replace fluoroscopy, because lateral fluoroscopy is still required to establish safe depth, and correct site of injection. However, ultrasound can be helpful when fluoroscopy alone is insufficient.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 11 条
[1]   Ultrasound guidance in caudal epidural needle placement [J].
Chen, CPC ;
Tang, SFT ;
Hsu, TC ;
Tsai, WC ;
Liu, HP ;
Chen, MJL ;
Date, E ;
Lew, HL .
ANESTHESIOLOGY, 2004, 101 (01) :181-184
[2]  
Munir MA, 2004, CAN J ANAESTH, V51, P915, DOI 10.1007/BF03018890
[3]  
Narouze Samer, 2008, Pain Pract, V8, P223, DOI 10.1111/j.1533-2500.2008.00221.x
[4]   Ultrasound-Guided Interventional Procedures in Pain Medicine: A Review of Anatomy, Sonoanatomy, and Procedures Part I: Nonaxial Structures [J].
Peng, Philip W. H. ;
Narouze, Samer .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (05) :458-474
[5]  
Plancarte R, 1993, CANC PAIN, P417
[6]  
RAJ PP, 2003, RADIOGRAPHIC IMAGING, P238
[7]  
Reig Enrique, 2005, Pain Pract, V5, P103, DOI 10.1111/j.1533-2500.2005.05206.x
[8]  
RO C, 1995, BASIC CLIN ANATOMY S, P241
[9]  
Toshniwal Gokul R, 2007, Pain Physician, V10, P661
[10]  
WALDMAN SD, 2007, PAIN MANAGEMENT, P1354