Pulse Artifact Detection in Simultaneous EEG-fMRI Recording Based on EEG Map Topography

被引:21
作者
Iannotti, Giannina R. [1 ]
Pittau, Francesca [1 ,2 ]
Michel, Christoph M. [1 ]
Vulliemoz, Serge [1 ,2 ]
Grouiller, Frederic [3 ]
机构
[1] Univ Hosp Geneva, Dept Fundamental Neurosci, Funct Brain Mapping Lab, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Dept Neurol, EEG & Epilepsy Unit, CH-1211 Geneva 14, Switzerland
[3] Univ Hosp Geneva, Dept Radiol & Med Informat, CH-1211 Geneva 14, Switzerland
基金
瑞士国家科学基金会;
关键词
EEG-fMRI; High-density EEG; Gradient artifact; Ballistocardiogram; Pulse artifact detection; EEG topography; FUNCTIONAL MRI; BALLISTOCARDIOGRAM ARTIFACT; SIMULTANEOUS EEG/FMRI; EPILEPTIC NETWORKS; FIELD-STRENGTH; REMOVAL; SCANNER; IDENTIFICATION; LOCALIZATION; COMBINATION;
D O I
10.1007/s10548-014-0409-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
One of the major artifact corrupting electroencephalogram (EEG) acquired during functional magnetic resonance imaging (fMRI) is the pulse artifact (PA). It is mainly due to the motion of the head and attached electrodes and wires in the magnetic field occurring after each heartbeat. In this study we propose a novel method to improve PA detection by considering the strong gradient and inversed polarity between left and right EEG electrodes. We acquired high-density EEG-fMRI (256 electrodes) with simultaneous electrocardiogram (ECG) at 3 T. PA was estimated as the voltage difference between right and left signals from the electrodes showing the strongest artifact (facial and temporal). Peaks were detected on this estimated signal and compared to the peaks in the ECG recording. We analyzed data from eleven healthy subjects, two epileptic patients and four healthy subjects with an insulating layer between electrodes and scalp. The accuracy of the two methods was assessed with three criteria: (i) standard deviation, (ii) kurtosis and (iii) confinement into the physiological range of the inter-peak intervals. We also checked whether the new method has an influence on the identification of epileptic spikes. Results show that estimated PA improved artifact detection in 15/17 cases, when compared to the ECG method. Moreover, epileptic spike identification was not altered by the correction. The proposed method improves the detection of pulse-related artifacts, particularly crucial when the ECG is of poor quality or cannot be recorded. It will contribute to enhance the quality of the EEG increasing the reliability of EEG-informed fMRI analysis.
引用
收藏
页码:21 / 32
页数:12
相关论文
共 42 条
  • [1] Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    Allen, PJ
    Polizzi, G
    Krakow, K
    Fish, DR
    Lemieux, L
    [J]. NEUROIMAGE, 1998, 8 (03) : 229 - 239
  • [2] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [3] [Anonymous], SECTION BIOL MED SCI
  • [4] Quality of EEG in simultaneous EEG-fMRI for epilepsy
    Bénar, CG
    Aghakhani, Y
    Wang, YH
    Izenberg, A
    Al-Asmi, A
    Dubeau, F
    Gotman, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2003, 114 (03) : 569 - 580
  • [5] SCOPOLAMINE EFFECTS ON VISUAL INFORMATION-PROCESSING, ATTENTION, AND EVENT-RELATED POTENTIAL MAP LATENCIES
    BRANDEIS, D
    NAYLOR, H
    HALLIDAY, R
    CALLAWAY, E
    YANO, L
    [J]. PSYCHOPHYSIOLOGY, 1992, 29 (03) : 315 - 336
  • [6] BOLD correlates of EEG topography reveal rapid resting-state network dynamics
    Britz, Juliane
    Van De Ville, Dimitri
    Michel, Christoph M.
    [J]. NEUROIMAGE, 2010, 52 (04) : 1162 - 1170
  • [7] Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions
    Brodbeck, Verena
    Lascano, Agustina M.
    Spinelli, Laurent
    Seeck, Margitta
    Michel, Christoph M.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (04) : 679 - 685
  • [8] Simultaneous EEG source localisation and artifact rejection during concurrent fMRI by means of spatial filtering
    Brookes, Matthew J.
    Mullinger, Karen J.
    Stevenson, Claire M.
    Morris, Peter G.
    Bowtell, Richard
    [J]. NEUROIMAGE, 2008, 40 (03) : 1090 - 1104
  • [9] Spatiotemporal Analysis of Multichannel EEG: CARTOOL
    Brunet, Denis
    Murray, Micah M.
    Michel, Christoph M.
    [J]. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2011, 2011
  • [10] Reference layer artefact subtraction (RLAS): A novel method of minimizing EEG artefacts during simultaneous fMRI
    Chowdhury, Muhammad E. H.
    Mullinger, Karen J.
    Glover, Paul
    Bowtell, Richard
    [J]. NEUROIMAGE, 2014, 84 : 307 - 319