Rapid and highly sensitive quantification of the anti-tuberculosis agents isoniazid, ethambutol, pyrazinamide, rifampicin and rifabutin in human plasma by UPLC-MS/MS

被引:18
|
作者
Wu, Lingjie [1 ,2 ,3 ]
Ye, Zhenjie [2 ]
Liu, Hui [2 ]
Guo, Hongliang [2 ]
Lin, Jing [4 ]
Zheng, Ling [2 ]
Chu, Nannan [2 ,5 ]
Liu, Xiaolong [1 ,2 ,3 ,4 ]
机构
[1] Fujian Med Univ, United Innovat Mengchao Hepatobiliary Technol Key, Mengchao Hepatobiliary Hosp, 312 Xihong Rd, Fuzhou 350025, Peoples R China
[2] Fujian Med Univ, Clin Res Ctr Phase 1, Mengchao Hepatobiliary Hosp, 312 Xihong Rd, Fuzhou 350025, Peoples R China
[3] Fujian Med Univ, Liver Ctr Fujian Prov, Fuzhou 350025, Peoples R China
[4] Fujian Med Univ, Dept Infect Dis, Fuzhou 350025, Peoples R China
[5] Wuxi Peoples Hosp, Drug Clin Study Ctr Phase 1, Wuxi 214023, Jiangsu, Peoples R China
关键词
UPLC-MS/MS; Anti-tuberculosis agent; Quantification method; Therapeutic drug monitoring; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; DRUGS; PHARMACOKINETICS; VALIDATION; HIV;
D O I
10.1016/j.jpba.2019.113076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the increased cases of multidrug- or rifampicin-resistant tuberculosis and co-infection with HIV globally, it is difficult to achieve ideal clinical responses because of poor drug absorption and drug-drug interactions. Herein, a bioanalytical UPLC-MS/MS method was developed and validated to quantify five anti-TB agents in human plasma samples for detecting blood drug concentrations to improve therapeutic effects. To overcome the matrix effects, stable isotope labeled analogue of each analyte was used for internal standardization. A simple single-step protein precipitation by acetonitrile was employed for the sample preparation, then the analytes including rifampicin, rifabutin, pyrazinamid, ethambutol, isoniazid and their isotope labeled internal standards (ILISs) were implemented on an HILIC silica column with a gradient mode. The linear range for each analyte was covering the peak drug concentration (C-max) in the 20 times diluted plasma samples. The coefficient of variation of intra- and inter-day precision was less than 17.0 %, and the accuracy ranged between 91.5 and 110.0 %. The extraction recoveries of all agents were >= 90.2 %, and the matrix effects with internal standard-normalization for all agents were 97.1-110.0 %. The optimal blood sampling time was designed basing on the results of stability validation. This UPLC-MS/MS method with a run time of 3.5 min was successfully applied to routine therapeutic monitoring of the five anti-TB agents in patient plasma. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A novel, rapid and simple UPLC-MS/MS method for quantification of favipiravir in human plasma: Application to a bioequivalence study
    Rezk, Mamdouh R.
    Badr, Kamal A.
    Abdel-Naby, Naglaa S.
    Ayyad, Magy M.
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (07)
  • [22] Rapid Quantification of Caffeine and Theobromine in Multiple Human Biofluids via UPLC-MS/MS
    Ptolemy, A.
    Tzioumis, E.
    Thomke, A.
    Rifai, S.
    Kellogg, M.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A228 - A228
  • [23] A high-throughput LC-MS/MS method for simultaneous determination of isoniazid, ethambutol and pyrazinamide in human plasma
    Prso, Kristian
    Zidekova, Nela
    Porvaznik, Igor
    Solovic, Ivan
    Mokry, Juraj
    Kertys, Martin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (02)
  • [24] A Case of Delusional Disorder With Abuse of Isoniazid, Rifampicin, Pyrazinamide, and Ethambutol, the First-Line Anti-tuberculosis Therapy Drugs in India
    Sathiyamoorthi, Sathiyanarayanan
    Pentapati, Siva Santosh Kumar
    Vullanki, Sai Sreeja
    Avula, Vijaya Chandra Reddy
    Aravindakshan, Rajeev
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [26] Simultaneous quantification of ambrisentan, macitentan and sitaxentan in human plasma using UPLC-MS/MS
    van de Velde, Daan
    Bahmany, Soma
    Hitzerd, Emilie
    van Domburg, Bart
    Versmissen, Jorie
    Danser, A. H. Jan
    Koch, Birgit C. P.
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (03)
  • [27] A highly sensitive and selective UPLC-MS/MS assay for the determination of enarodustat (JTZ-951) in human plasma
    Pai, Sudhakar
    Huang, Mike Qingtao
    Maki, Koichi
    Waldron, Michael
    Yoshikawa, Tomonori
    Keller, Tara
    Burnett, James
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1176
  • [28] Development and Validation of an Ecofriendly, Rapid, Simple and Sensitive UPLC-MS/MS Method for Entrectinib Quantification in Plasma for Therapeutic Drug Monitoring
    Ali, Essam A.
    Iqbal, Muzaffar
    Mostafa, Gamal A. E.
    Al Salahi, Rashad
    SEPARATIONS, 2023, 10 (09)
  • [29] Development and validation of a highly sensitive UPLC-MS/MS method for the determination of Huperzine A in rat plasma
    Zhang, Kejun
    Wang, Haizhou
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (11)
  • [30] Method for simultaneous analysis of nine second-line anti-tuberculosis drugs using UPLC-MS/MS
    Han, Minje
    Jun, Sun Hee
    Lee, Jae Ho
    Park, Kyoung Un
    Song, Junghan
    Song, Sang Hoon
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2013, 68 (09) : 2066 - 2073