Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging
被引:182
|
作者:
Alfakih, K
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Alfakih, K
Plein, S
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Plein, S
Bloomer, T
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Bloomer, T
Jones, T
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Jones, T
Ridgway, J
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Ridgway, J
Sivananthan, M
论文数: 0引用数: 0
h-index: 0
机构:Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
Sivananthan, M
机构:
[1] Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Leeds Gen Infirm, Dept Phys Med, Leeds LS1 3EX, W Yorkshire, England
magnetic resonance imaging;
heart;
steady-state imaging;
right ventricular volumes;
observer variability;
D O I:
10.1002/jmri.10329
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To compare right ventricular (RV) volume measurements and their, reproducibility between axial and short axis orientation acquisition-techniques. Materials and Methods: Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects: The observer variabilities were assessed and the deft ventricle (LV) and RV stroke volumes (SV) were,compared. Results: There was a significant and systematic difference in the EDV and ESV volumes between the axial and short axis methods. The latter method resulted in larger volumes (mean bias EDV 7.5 +/- 13.2, 4.7% difference, ESV 7.2 +/- 8.6, 10.7% difference). The axial method had lower intra- and, interobserver variability than: the short axis method. The standard deviation of the difference (SDD) and the limits of agreement were consistently lower for the axial method. The mean differences between LV and RV stroke volumes expressed as mean +/- SD (r(2) =correlation coefficient) were axial 7.6 +/- 9.1 (r(2) +/- 0.93); and short axis 7.4 +/- 10.8 (r(2) = 0.90). Conclusion: There is,a significant systematic difference. between volumes measured using the two different orientations. The axial orientation resulted in better inter- and intraobserver reproducibility.
机构:
Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Moghari, Mehdi H.
Komarlu, Rukmini
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USABoston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Komarlu, Rukmini
Annese, David
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USABoston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Annese, David
Geva, Tal
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Geva, Tal
Powell, Andrew J.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA