Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging

被引:182
|
作者
Alfakih, K
Plein, S
Bloomer, T
Jones, T
Ridgway, J
Sivananthan, M
机构
[1] Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Leeds Gen Infirm, Dept Phys Med, Leeds LS1 3EX, W Yorkshire, England
关键词
magnetic resonance imaging; heart; steady-state imaging; right ventricular volumes; observer variability;
D O I
10.1002/jmri.10329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare right ventricular (RV) volume measurements and their, reproducibility between axial and short axis orientation acquisition-techniques. Materials and Methods: Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects: The observer variabilities were assessed and the deft ventricle (LV) and RV stroke volumes (SV) were,compared. Results: There was a significant and systematic difference in the EDV and ESV volumes between the axial and short axis methods. The latter method resulted in larger volumes (mean bias EDV 7.5 +/- 13.2, 4.7% difference, ESV 7.2 +/- 8.6, 10.7% difference). The axial method had lower intra- and, interobserver variability than: the short axis method. The standard deviation of the difference (SDD) and the limits of agreement were consistently lower for the axial method. The mean differences between LV and RV stroke volumes expressed as mean +/- SD (r(2) =correlation coefficient) were axial 7.6 +/- 9.1 (r(2) +/- 0.93); and short axis 7.4 +/- 10.8 (r(2) = 0.90). Conclusion: There is,a significant systematic difference. between volumes measured using the two different orientations. The axial orientation resulted in better inter- and intraobserver reproducibility.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [1] Comparison of right ventricular volume measurement between segmented K-space gradient-echo and steady-state free precession magnetic resonance Imaging
    Alfakih, K
    Thiele, H
    Plein, S
    Bainbridge, GJ
    Ridgway, JP
    Sivananthan, MU
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (03) : 253 - 258
  • [2] Cardiac magnetic resonance imaging left ventricular stroke volume assessment accuracy comparison between short axis steady state free precession and flow velocity encoding gradients
    Troupis, C. J.
    Ford, C.
    Moir, S. W.
    Troupis, J. M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 199 - 200
  • [3] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [4] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [5] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW LETTERS, 1958, 1 (11) : 429 - 430
  • [6] Diagnosis of Left Ventricular Diastolic Dysfunction Using Cardiac Magnetic Resonance Imaging: Comparison of Volume-Time Curves Derived from Long- and Short-Axis Cine Steady-State Free Precession Datasets
    Schaafs, Lars-Arne
    Wyschkon, Sebastian
    Elgeti, Matthias
    Nagel, Sebastian Niko
    Knebel, Fabian
    Steffen, Ingo G.
    Makowski, Marcus R.
    Hamm, Bernd
    Elgeti, Thomas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (08): : 764 - 775
  • [7] Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging
    Hudsmith, LE
    Petersen, SE
    Francis, JM
    Robson, MD
    Neubauer, S
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) : 775 - 782
  • [8] Quantitative analysis using steady-state free precession nuclear magnetic resonance
    Azeredo, RBD
    Colnago, LA
    Engelsberg, M
    ANALYTICAL CHEMISTRY, 2000, 72 (11) : 2401 - 2405
  • [9] Accuracy of Right and Left Ventricular Functional Assessment by Short-Axis vs Axial Cine Steady-State Free-Precession Magnetic Resonance Imaging: Intrapatient Correlation With Main Pulmonary Artery and Ascending Aorta Phase-Contrast Flow Measurements
    James, Susan H.
    Wald, Rachel
    Wintersperger, Bernd J.
    Jimenez-Juan, Laura
    Deva, Djeven
    Crean, Andrew M.
    Elsie Nguyen
    Paul, Narinder S.
    Ley, Sebastian
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (03): : 213 - 219
  • [10] Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance
    Sievers, Burkhard
    Addo, Marvin
    Breuckmann, Frank
    Barkhausen, Joerg
    Erbel, Raimund