Optimization of hydrogen feeding procedure in PEM fuel cell systems for transportation

被引:28
作者
Migliardini, F. [1 ]
Capasso, C. [1 ]
Corbo, P. [1 ]
机构
[1] Natl Res Council Italy, Ist Motori, I-80125 Naples, Italy
关键词
PEM fuel cells; Fuel cell system; Dead-end; Hydrogen recirculation; Fuel cell durability; PEFC STACK; MEMBRANE;
D O I
10.1016/j.ijhydene.2014.08.070
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The hydrogen feeding sub-system is one of balance of plant (BOP) components necessary for the correct operation of a fuel cell system (FCS). In this paper the performance of a 6 kW PEM (Proton Exchange Membrane) FCS, able to work with two fuel feeding procedures (dead-end or flow-through), was experimentally evaluated with the aim to highlight the effect of the anode operation mode on stack efficiency and durability. The FCS operated at low reactant pressure (<50 kPa) and temperature (<330 K), without external humidification. The experiments were performed in both steady state and dynamic conditions. The performance of some cells in dead-end mode worsened during transient phases, while a more stable working was observed with fuel recirculation. This behavior evidenced the positive role of the flow-through procedure in controlling flooding phenomena, with the additional advantage to simplify the management issues related to hydrogen purge and air stoichiometric ratio. The flow-through modality resulted a useful way to optimize the stack efficiency and to reduce the risks of fast degradation due to reactant starvation during transient operative phases. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21746 / 21752
页数:7
相关论文
共 18 条
[1]   Fuel cell systems for transportation: Status and trends [J].
Ahluwalia, Rajesh K. ;
Wang, Xiaohua. .
JOURNAL OF POWER SOURCES, 2008, 177 (01) :167-176
[2]   Direct hydrogen fuel cell systems for hybrid vehicles [J].
Ahluwalia, RK ;
Wang, X .
JOURNAL OF POWER SOURCES, 2005, 139 (1-2) :152-164
[3]   Optimization of purge cycle for dead-ended anode fuel cell operation [J].
Chen, Jixin ;
Siegel, Jason B. ;
Stefanopoulou, Anna G. ;
Waldecker, James R. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (12) :5092-5105
[4]   Performance investigation of 2.4 kW PEM fuel cell stack in vehicles [J].
Corbo, P. ;
Migliardini, F. ;
Veneri, O. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (17) :4340-4349
[5]   Experimental assessment of energy-management strategies in fuel-cell propulsion systems [J].
Corbo, P ;
Corcione, FE ;
Migliardini, F ;
Veneri, O .
JOURNAL OF POWER SOURCES, 2006, 157 (02) :799-808
[6]  
Corbo P, 2011, GREEN ENERGY TECHNOL, P1, DOI 10.1007/978-0-85729-136-3
[7]   Dynamic behaviour of hydrogen fuel cells for automotive application [J].
Corbo, P. ;
Migliardini, F. ;
Veneri, O. .
RENEWABLE ENERGY, 2009, 34 (08) :1955-1961
[8]   Experimental analysis and management issues of a hydrogen fuel cell system for stationary and mobile application [J].
Corbo, Pasquale ;
Migliardini, Fortunato ;
Veneri, Ottorino .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (08) :2365-2374
[9]   PEFC Stack Operating in Anodic Dead End Mode [J].
Dumercy, L. ;
Pera, M-C ;
Glises, R. ;
Hissel, D. ;
Hamandi, S. ;
Badin, F. ;
Kauffmann, J-M .
FUEL CELLS, 2004, 4 (04) :352-357
[10]   Performance improvement of a PEMFC system controlling the cathode outlet air flow [J].
Feroldi, Diego ;
Serra, Maria ;
Riera, Jordi .
JOURNAL OF POWER SOURCES, 2007, 169 (01) :205-212