Strain analysis of anterior resin-bonded fixed dental prostheses with different thicknesses of high translucent zirconia

被引:0
作者
Noda, Michiko [1 ]
Omori, Satoshi [1 ]
Nemoto, Reina [1 ]
Sukumoda, Erika [1 ]
Takita, Mina [1 ]
Foxton, Richard [2 ]
Nozaki, Kosuke [1 ]
Miura, Hiroyuki [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Div Oral Hlth Sci, Dept Fixed Prosthodont, Tokyo, Japan
[2] Kings Coll London, Fac Dent Oral & Craniofacial Sci, Restorat Dent, London, England
基金
日本学术振兴会;
关键词
Anterior restoration; High translucent zirconia; Resin-bonded fixed dental prostheses; Retainer thickness; Strain analysis; IN-VITRO; PARTIAL DENTURES; RESISTANCE; DESIGN; VIVO;
D O I
10.1016/j.jds.2020.10.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: High translucent zirconia has been used as a new monolithic zirconia prosthesis, which has the potential to make anterior resin-bonded fixed dental prostheses (RBFDPs) without veneering porcelain. However, it is unclear whether the RBFDPs retainer can be thinned as much as conventional zirconia RBFDPs. The aim of this study was to assess the usability of high translucent zirconia RBFDPs with a thin retainer thickness by evaluating differences in retainer thickness on the surface strain. Materials and methods: A model with a missing upper lateral incisor was used. The abutment teeth were upper central incisor and canine. Three types of RBFDPs were fabricated as follows: metal RBFDPs with a retainer thickness of 0.8 mm (0.8M), and high translucent zirconia RBFDPs with a retainer thicknesses of 0.8 and 0.5 mm (0.8Z, 0.5Z) (n = 10). The fitness of the margins was evaluated by the silicone replica technique. The surface strain of each retainer under static loading was measured and statistically analyzed using a t-test with Bonferroni correction. Results: The marginal fitness of all RBFDPs was under 76.1 mu m, which was clinically acceptable. Each strain of the 0.8Z and 0.5Z groups was significantly lower than that of the 0.8M (p < 0.05). There was no difference in strain of the zirconia RBFDPs even if the retainer thickness was changed. Conclusion: Our results suggest that the high translucent zirconia RBFDPs can be manufactured with a retainer thickness of 0.5 mm, which reduces the amount of tooth preparation compared to the metal RBFDPs. (C) 2020 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V.
引用
收藏
页码:628 / 635
页数:8
相关论文
共 37 条
[1]   Five-year success rate of resin-bonded fixed partial dentures: A systematic review [J].
Abd Alraheam, Islam ;
Ngoc, Caroline Nguyen ;
Wiesen, Christopher A. ;
Donovan, Terence E. .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (01) :40-50
[2]   The Effect of Ceramic Type and Background Color on Shade Reproducibility of All-Ceramic Restorations [J].
Al Hamad, Khaled Q. ;
Obaidat, Ismaeel I. ;
Baba, Nadim Z. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (06) :511-517
[3]   Effects of alumina-blasting pressure on the bonding to super/ultra-translucent zirconia [J].
Aung, San San May Phyo ;
Takagaki, Tomohiro ;
Lyann, Sai Kham ;
Ikeda, Masaomi ;
Inokoshi, Masanao ;
Sadr, Alireza ;
Nikaido, Toru ;
Tagami, Junji .
DENTAL MATERIALS, 2019, 35 (05) :730-739
[4]   Evaluation of Stress Distribution in Tooth-Supported Fixed Dental Prostheses Made of Translucent Zirconia with Variations in Framework Designs: A Three-Dimensional Finite Element Analysis [J].
Bakitian, Fahad ;
Papia, Evaggelia ;
Larsson, Christel ;
Vult von Steyern, Per .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04) :315-322
[5]  
Blatz Markus B, 2016, Compend Contin Educ Dent, V37, P611
[6]  
Bömicke W, 2018, J PROSTHET DENT, V119, P89, DOI 10.1016/j.prosdent.2017.03.006
[7]  
Brokos Y., 2015, International Journal of Advances in Case Reports, V2, P1396
[8]   Resin bonded bridges: techniques for success [J].
Durey, K. A. ;
Nixon, P. J. ;
Robinson, S. ;
Chan, M. F. W. -Y. .
BRITISH DENTAL JOURNAL, 2011, 211 (03) :113-118
[9]   A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application [J].
Epprecht, Alyssa ;
Zeltner, Marco ;
Benic, Goran ;
Ozcan, Mutlu .
CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2018, 4 (01) :13-18
[10]   ANATOMIC GUIDE FOR REDUCTION OF ENAMEL FOR ACID-ETCHED RETAINERS [J].
FERRARI, M ;
CAGIDIACO, MC ;
BERTELLI, E .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 58 (01) :106-110