Axial Anisotropic Conductivity Imaging Based on Projected Current Density in MREIT

被引:10
作者
Nam, Hyun Soo [1 ]
Kwon, Oh In [1 ]
机构
[1] Konkuk Univ, Dept Math, Seoul 143701, South Korea
关键词
Axial anisotropic conductivity; current density; magnetic resonance electrical impedance tomography (MREIT); magnetic resonance imaging (MRI); ELECTRICAL-IMPEDANCE TOMOGRAPHY; MAGNETIC-FLUX DENSITY; ONE-COMPONENT; RECONSTRUCTION; ALGORITHM; DECOMPOSITION; PERFORMANCE; RESOLUTION; CONTRAST;
D O I
10.1109/TMI.2009.2036440
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An aim of magnetic resonance electrical impedance tomography (MREIT) is to visualize the internal current density and/or the conductivity of an imaging object. In MREIT, it is desirable to use just one component of the internal magnetic flux density vector B = (B-x, B-y,B- B-z) caused by the injected current, measured without rotating the object. We present a method of visualizing the axial anisotropic conductivity tensor by use of the measured magnetic flux density B-z data. The method involves the use of a projected current density, which is a uniquely and stably determined component of the internal current generated by the injected current, derived from the measured B-z data. Each component of the axial anisotropic conductivity is recovered by matching the measured B-z data with a determined intermediate isotropic conductivity and the projected currents. Results from numerical simulations demonstrate that the proposed algorithm is robust to noise and stably determines the anisotropic conductivity tensor on the imaging slice. For a practical implementation, we studied a postmortem canine brain case to visualize each component of the anisotropic conductivity. We observed that the reconstructed anisotropic conductivity images clearly reflects the anisotropic property of the white matter in the direction parallel to its fibers.
引用
收藏
页码:781 / 789
页数:9
相关论文
共 32 条
[1]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[2]  
Birgül Ö, 2003, PHYS MED BIOL, V48, P653, DOI 10.1088/0031-9155/48/5/307
[3]   Contrast and spatial resolution in MREIT using low amplitude current [J].
Birgul, Ozlem ;
Hamamura, Mark J. ;
Muftuler, L. Tugan ;
Nalcioglu, Orhan .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) :5035-5049
[4]   Anisotropic conductivity imaging with MREIT using equipotential projection algorithm [J].
Degirmenci, Evren ;
Eyuboglu, B. Murat .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24) :7229-7242
[5]  
Gilbarg D., 1977, Grundlehren der Mathematischen Wissenschaften, V224
[6]   Measurement of ion diffusion using magnetic resonance electrical impedance tomography [J].
Hamamura, Mark J. ;
Muftuler, L. Tugan ;
Birgul, Ozlem ;
Nalcioglu, Orhan .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2753-2762
[7]  
Ider Y Z, 1998, ELEKTRIK, V6, P215
[8]   Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density [J].
Ider, YZ ;
Onart, S .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :281-294
[9]   INVIVO DETECTION OF APPLIED ELECTRIC CURRENTS BY MAGNETIC-RESONANCE IMAGING [J].
JOY, M ;
SCOTT, G ;
HENKELMAN, M .
MAGNETIC RESONANCE IMAGING, 1989, 7 (01) :89-94
[10]  
Joy MLG, 2004, P ANN INT IEEE EMBS, V26, P5315