Estimation of Radiation Exposure to Workers During [18F] FDG PET/CT Procedures at Molecular Imaging Center, Oman

被引:11
作者
Al-Aamria, Marwa [1 ]
AL-Balushia, Naima [1 ]
Bailey, Dale [2 ]
机构
[1] Royal Hosp, Mol Imaging Ctr, Nucl Med Dept, Muscat, Oman
[2] Royal North Shore Hosp, Nucl Med Dept, St Leonards, NSW, Australia
关键词
Electronic personal dosimeters; PET/CT; radiation exposure; survey meter;
D O I
10.1016/j.jmir.2019.05.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron-emission tomography (PET) is the imaging modality of choice in oncology. In addition, there are several indications for using PET in cardiology and neurology. The main radiotracer used is the radiolabeled glucose analog [F-18] fluorodeoxyglucose ([F-18] FDG). The high-energy annihilation radiation from positron emission may lead to significant radiation exposure to medical imaging professionals such as technologists and staff nurses, patients, and direct acquaintances of the patient. In this cross-sectional observational study, the effective dose to workers in the Molecular Imaging Center from patients injected with [F-18] FDG is assessed. Dose rates were estimated by a calibrated, portable gamma-ray survey meter at 0.3, 0.5, 1.0, and 2.0 m from 70 patients who underwent whole body [F-18] FDG PET/CT procedure immediately and 2 hours post-injection. Electronic personal dosimeters were used to determine the radiation doses per PET/CT imaging for the five staff who directly involved in handling of the injected patients. The staff includes two technologists, two staff nurses, and one medical physicist. The mean dose rates from patients after injection and standard deviation (mu Sv/h) for the four distances were 98.1 +/- 20.0, 55.3 +/- 20.0, 28.2 +/- 10.0, and 10.8 +/- 5.0, respectively. After 2 hours, the measurements significantly dropped to 45.7 +/- 10.0, 23.6 +/- 10.0, 9.9 +/- 4.0, and 3.7 +/- 1.0 mu Sv/h. The average effective dose values for a technologist from injected patients throughout the procedure of PET/CT study was 4.17 mu Sv per study or 5 mSv/y. This is less than the annual limit recommended by the International Commission on Radiological Protection of 20 mSv/y received in the medical imaging profession.
引用
收藏
页码:565 / 570
页数:6
相关论文
共 14 条
[1]  
Abe R., 2010, IAEA
[2]  
[Anonymous], 2007, IPCC 4 ASSESSMENT RE, DOI [10.1037/e518422011-002, DOI 10.1037/E518422011-002]
[3]   18F-FDG PET and PET/CT in the Evaluation of Cancer Treatment Response [J].
Ben-Haim, Simona ;
Ell, Peter .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) :88-99
[4]  
Biodex Medical system, 2005, NUCL MED MOL IM DEV, P108
[5]  
Cho IH, 2014, HELL J NUCL MED, V17, P13, DOI 10.1967/s002449910113
[6]   RADIATION-DOSES FROM NUCLEAR-MEDICINE PATIENTS TO AN IMAGING TECHNOLOGIST - RELATION TO ICRP RECOMMENDATIONS FOR PREGNANT WORKERS [J].
CLARKE, EA ;
THOMSON, WH ;
NOTGHI, A ;
HARDING, LK .
NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (11) :795-798
[7]  
Dalianis K., 2014, PHYS MEDICA, V30, P45, DOI [10.1016/j.ejmp.2014.07.134, DOI 10.1016/J.EJMP.2014.07.134]
[8]  
Demir M, 2010, NUKLEONIKA, V55, P107
[9]   Radiation exposure to nuclear medicine staffs during 18F-FDG PET/CT procedures at Ramathibodi Hospital [J].
Donmoon, T. ;
Chamroonrat, W. ;
Tuntawiroon, M. .
13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
[10]  
Jha Ashish Kumar, 2015, World J Nucl Med, V14, P189, DOI 10.4103/1450-1147.163252