Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry

被引:12
作者
Yang, Hao-Chun [1 ]
Chang, Cheng-Hao [1 ]
Urban, Pawel L. [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Appl Chem, Hsinchu, Taiwan
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2017年 / 125期
关键词
Chemistry; Issue; 125; Automation; chemical analysis; extraction; mass spectrometry; sample preparation; volatile organic compounds; GAS-PHASE; SYSTEM; CHROMATOGRAPHY; SAMPLES;
D O I
10.3791/56008
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Chemical analysis of volatile and semivolatile compounds dissolved in liquid samples can be challenging. The dissolved components need to be brought to the gas phase, and efficiently transferred to a detection system. Fizzy extraction takes advantage of the effervescence phenomenon. First, a carrier gas (here, carbon dioxide) is dissolved in the sample by applying overpressure and stirring the sample. Second, the sample chamber is decompressed abruptly. Decompression leads to the formation of numerous carrier gas bubbles in the sample liquid. These bubbles assist the release of the dissolved analyte species from the liquid to the gas phase. The released analytes are immediately transferred to the atmospheric pressure chemical ionization interface of a triple quadrupole mass spectrometer. The ionizable analyte species give rise to mass spectrometric signals in the time domain. Because the release of the analyte species occurs over short periods of time (a few seconds), the temporal signals have high amplitudes and high signal-to-noise ratios. The amplitudes and areas of the temporal peaks can then be correlated with concentrations of the analytes in the liquid samples subjected to fizzy extraction, which enables quantitative analysis. The advantages of fizzy extraction include: simplicity, speed, and limited use of chemicals (solvents).
引用
收藏
页数:9
相关论文
共 21 条
  • [1] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HAEGELE, KD
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (14) : 2369 - 2373
  • [2] SUBPICOGRAM DETECTION SYSTEM FOR GAS-PHASE ANALYSIS BASED UPON ATMOSPHERIC-PRESSURE IONIZATION (API) MASS-SPECTROMETRY
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HORNING, MG
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (06) : 706 - 710
  • [3] Fizzy Extraction of Volatile and Semivolatile Compounds into the Gas Phase
    Chang, Cheng-Hao
    Urban, Pawel L.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (17) : 8735 - 8740
  • [4] Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation
    Chen, HW
    Venter, A
    Cooks, RG
    [J]. CHEMICAL COMMUNICATIONS, 2006, (19) : 2042 - 2044
  • [5] On-line monitoring of Soxhlet extraction by chromatography and mass spectrometry to reveal temporal extract profiles
    Chen, Ssu-Ying
    Urban, Pawel L.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 881 : 74 - 81
  • [6] Generation of Multiply Charged Peptides and Proteins by Radio Frequency Acoustic Desorption and Ionization for Mass Spectrometric Detection
    Dixon, R. Brent
    Sampson, Jason S.
    Muddiman, David C.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (04) : 597 - 600
  • [7] Easy ambient sonic-spray ionization-membrane interface mass spectrometry for direct analysis of solution constituents
    Haddad, Renato
    Sparrapan, Regina
    Kotiaho, Tapio
    Eberlin, Marcos N.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (03) : 898 - 903
  • [8] Hakim I. A., 2000, Journal of Food Composition and Analysis, V13, P329, DOI 10.1006/jfca.1999.0862
  • [9] Automated on-line liquid-liquid extraction system for temporal mass spectrometric analysis of dynamic samples
    Hsieh, Kai-Ta
    Liu, Pei-Han
    Urban, Pawel L.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 894 : 35 - 43
  • [10] Automated system for extraction and instantaneous analysis of millimeter-sized samples
    Hu, Jie-Bi
    Chen, Ssu-Ying
    Wu, June-Tai
    Chen, Yu-Chie
    Urban, Pawel L.
    [J]. RSC ADVANCES, 2014, 4 (21) : 10693 - 10701