Comparison of computerized mass detection in digital breast tomosynthesis (DBT) mammograms and conventional mammograms

被引:0
|
作者
Chan, Heang-Ping [1 ]
Wei, Jun [1 ]
Sahiner, Berkman [1 ]
Hadjiiski, Lubomir [1 ]
Helvie, Mark A. [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
来源
MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS | 2009年 / 7260卷
关键词
Digital breast tomosynthesis; conventional mammograms; computer-aided detection; mass; SART; AIDED DETECTION; SYSTEM;
D O I
10.1117/12.813851
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
We are developing a CAD system for mass detection on digital breast tomosynthesis (DBT) mammograms. In this study, we compared the detection accuracy on DBT and conventional screen-film mammograms (SFMs). DBT mammograms were acquired with a GE prototype system at the University of Michigan. 47 cases containing the CC- and MLO-view DBT mammograms of the breast with a biopsy-proven mass and the corresponding two-view SFMs of the same breast were collected. Subjective judgment showed that the masses were much more conspicuous on DBT slices than on SFMs. The CAD system for DBT includes two parallel processes, one performs mass detection in the reconstructed DBT volume, and the other in the projection view (PV) images. The mass likelihood scores estimated for each mass candidate in the two processes are merged to differentiate masses and false positives (FPs). For detection on SFMs, we previously developed a dual system approach by fusing two single CAD systems optimized for detection of average and subtle masses, respectively. A trained neural network is used to merge the mass likelihood scores of the two single systems to reduce FPs. At the case-based sensitivities of 80% and 85%, mass detection in the DBT volume resulted in an average of 0.72 and 1.06 FPs/view, and detection in the SFMs yielded 0.94 and 1.67 FPs/view, respectively. The difference fell short of statistical significance (p=0.07) by JAFROC analysis. Study is underway to collect a larger data set and to further improve the DBT CAD system.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Combination of conspicuity improved synthetic mammograms and digital breast tomosynthesis: A promising approach for mass detection
    Kim, Seong Tae
    Kim, Dae Hoe
    Ro, Yong Man
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [2] Mass detection in reconstructed digital breast tomosynthesis volumes with a computer-aided detection system trained on 2D mammograms
    van Schie, Guido
    Wallis, Matthew G.
    Leifland, Karin
    Danielsson, Mats
    Karssemeijer, Nico
    MEDICAL PHYSICS, 2013, 40 (04)
  • [3] Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms: An Observer Performance Study
    Chan, Heang-Ping
    Helvie, Mark A.
    Hadjiiski, Lubomir
    Jeffries, Deborah O.
    Klein, Katherine A.
    Neal, Colleen H.
    Noroozian, Mitra
    Paramagul, Chintana
    Roubidoux, Marilyn A.
    ACADEMIC RADIOLOGY, 2017, 24 (11) : 1372 - 1379
  • [4] Effect of Arrival of Prior Mammograms on Recall Negation for Screening Mammograms Performed With Digital Breast Tomosynthesis in a Clinical Setting
    Hardesty, Lara A.
    Lind, Kimberly E.
    Gutierrez, Eric J.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (09) : 1293 - 1299
  • [5] Impact of prior mammograms on combined reading of digital mammography and digital breast tomosynthesis
    Kim, Won Hwa
    Chang, Jung Min
    Koo, Hye Ryoung
    Seo, Mirinae
    Bae, Min Sun
    Lee, Joongyub
    Moon, Woo Kyung
    ACTA RADIOLOGICA, 2017, 58 (02) : 148 - 155
  • [6] Predicting Breast Density of Digital Breast Tomosynthesis from 2D Mammograms
    Yeh, Jinn-Yi
    Lin, Tu-Liang
    Chan, Siwa
    IETE JOURNAL OF RESEARCH, 2023, 69 (06) : 3132 - 3143
  • [7] Regularized discriminant analysis for breast mass detection on full field digital mammograms
    Wei, Jun
    Sahiner, Berkman
    Zhang, Yiheng
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Zhou, Chuan
    Ge, Jun
    Wu, Yi-Ta
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [8] Comparison of breast percent density estimated from digital mammograms and central reconstructed tomosynthesis slice images
    Bakic, Predrag R.
    Kontos, Despina
    Troxel, Andrea B.
    Maidment, Andrew
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 674 - +
  • [9] Artificial intelligence computer-aided detection enhances synthesized mammograms: comparison with original digital mammograms alone and in combination with tomosynthesis images in an experimental setting
    Uematsu, Takayoshi
    Nakashima, Kazuaki
    Harada, Taiyo Leopoldo
    Nasu, Hatsuko
    Igarashi, Tatsuya
    BREAST CANCER, 2023, 30 (01) : 46 - 55
  • [10] Artificial intelligence computer-aided detection enhances synthesized mammograms: comparison with original digital mammograms alone and in combination with tomosynthesis images in an experimental setting
    Takayoshi Uematsu
    Kazuaki Nakashima
    Taiyo Leopoldo Harada
    Hatsuko Nasu
    Tatsuya Igarashi
    Breast Cancer, 2023, 30 : 46 - 55