共 171 条
Chiral Capillary Electrokinetic Chromatography: Principle and Applications, Detection and Identification, Design of Experiment, and Exploration of Chiral Recognition Using Molecular Modeling
被引:36
作者:
El Deeb, Sami
[1
]
Silva, Camilla Fonseca
[2
]
Nascimento Junior, Clebio Soares
[2
]
Hanafi, Rasha Sayed
[3
]
Borges, Keyller Bastos
[2
]
机构:
[1] Tech Univ Carolo Wilhelmina Braunschweig, Inst Med & Pharmaceut Chem, D-38106 Braunschweig, Germany
[2] Univ Fed Sao Joao del Rei UFSJ, Dept Ciencias Nat, Praca Dom Helvecio 74, BR-36301160 Sao Joao Del Rei, MG, Brazil
[3] German Univ Cairo, Fac Pharm & Biotechnol, Dept Pharmaceut Chem, Cairo 11835, Egypt
来源:
关键词:
chiral capillary electrokinetic chromatography;
enantioseparation;
chiral selector;
capillary electrophoresis;
Quality by Design;
enantiomers;
capillary electrophoresis-mass spectrometry;
enantiomeric impurity;
molecular modeling;
chiral recognition;
TANDEM MASS-SPECTROMETRY;
BETA-CYCLODEXTRIN DERIVATIVES;
ENANTIOMERIC SEPARATION;
IONIC LIQUIDS;
ELECTROMIGRATION METHODS;
MIGRATION ORDER;
ENANTIOSELECTIVE ANALYSIS;
CHARGED CYCLODEXTRINS;
FILLING TECHNIQUE;
AMINO-ACIDS;
D O I:
10.3390/molecules26102841
中图分类号:
Q5 [生物化学];
Q7 [分子生物学];
学科分类号:
071010 ;
081704 ;
摘要:
This work reviews the literature of chiral capillary electrokinetic chromatography from January 2016 to March 2021. This is done to explore the state-of-the-art approach and recent developments carried out in this field. The separation principle of the technique is described and supported with simple graphical illustrations, showing migration under normal and reversed polarity modes of the separation voltage. The most relevant applications of the technique for enantioseparation of drugs and other enantiomeric molecules in different fields using chiral selectors in single, dual, or multiple systems are highlighted. Measures to improve the detection sensitivity of chiral capillary electrokinetic chromatography with UV detector are discussed, and the alternative aspects are explored, besides special emphases to hyphenation compatibility to mass spectrometry. Partial filling and counter migration techniques are described. Indirect identification of the separated enantiomers and the determination of enantiomeric migration order are mentioned. The application of Quality by Design principles to facilitate method development, optimization, and validation is presented. The elucidation and explanation of chiral recognition in molecular bases are discussed with special focus on the role of molecular modeling.
引用
收藏
页数:31
相关论文